Manual

CLR−...
Festo CLR−... 0912d English
32
3. Turn the clamping finger with a spanner
wrench. The clamping finger will then be
released from the piston rod.
For counter holding, the maximum per
mitted torque on the guide sleeve must
not be exceeded (see chapter Mechanical
installation").
A suitable pull−off device must be used if
the clamping finger sticks.
S Order the wearing
parts as specified.
S Always send the defective product to Festo.
S Make sure that the CLR−... is overhauled only by our repair service.
The repair process calls for delicate setting work.
Please describe the fault and the operating conditions in your correspondence.
11 Accessories
Designation Type
Foot mounting HNA−...
Flange mounting FNC−...
Start−up valve HEL−.../HEM−...
One−way flow control valve GRLA−...
Non−return valve HGL−...
Compressed air reservoir VZS−...
Proximity switch SME−8−.../SMT−8−...
Clamping finger CLR−...FS
Fig.23