Specification
Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II, as amended by Commission Regulation (EU) 2015/830 - United Kingdom (UK)
CLEANER F3 EXPRESS 400ML (It1c)
4/12
Promptly isolate the scene by removing all persons from the vicinity of the incident if 
there is a fire. No action shall be taken involving any personal risk or without 
suitable training. Move containers from fire area if this can be done without risk.
Use water spray to keep fire-exposed containers cool.
Hazardous combustion 
products
Hazards from the 
substance or mixture
Decomposition products may include the following materials:
carbon dioxide
carbon monoxide
nitrogen oxides
sulfur oxides
phosphorus oxides
halogenated compounds
metal oxide/oxides
In a fire or if heated, a pressure increase will occur and the container may burst, with 
the risk of a subsequent explosion. Gas may accumulate in low or confined areas 
or travel a considerable distance to a source of ignition and flash back, causing fire 
or explosion. Bursting aerosol containers may be propelled from a fire at high speed.
Runoff to sewer may create fire or explosion hazard.
Fire-fighters should wear appropriate protective equipment and self-contained 
breathing apparatus (SCBA) with a full face-piece operated in positive pressure 
mode. Clothing for fire-fighters (including helmets, protective boots and gloves)
conforming to European standard EN 469 will provide a basic level of protection for 
chemical incidents.
Special protective 
equipment for fire-fighters
Use an extinguishing agent suitable for the surrounding fire.
5.1 Extinguishing media
:
:
:
None known.
Suitable extinguishing 
media
:
Unsuitable extinguishing 
media
:
SECTION 5: Firefighting measures
5.2 Special hazards arising from the substance or mixture
5.3 Advice for firefighters
Special protective actions 
for fire-fighters
:
6.2 Environmental 
precautions
Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains 
and sewers. Inform the relevant authorities if the product has caused environmental 
pollution (sewers, waterways, soil or air).
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and 
explosion-proof equipment. Dilute with water and mop up if water-soluble.
Alternatively, or if water-insoluble, absorb with an inert dry material and place in an 
appropriate waste disposal container. Dispose of via a licensed waste disposal 
contractor.
Small spill
:
6.3 Methods and material for containment and cleaning up
SECTION 6: Accidental release measures
6.1 Personal precautions, protective equipment and emergency procedures
For non-emergency 
personnel
:
For emergency responders
:
No action shall be taken involving any personal risk or without suitable training.
Evacuate surrounding areas. Keep unnecessary and unprotected personnel from 
entering. In the case of aerosols being ruptured, care should be taken due to the 
rapid escape of the pressurised contents and propellant. If a large number of 
containers are ruptured, treat as a bulk material spillage according to the 
instructions in the clean-up section. Do not touch or walk through spilt material.
Shut off all ignition sources. No flares, smoking or flames in hazard area. Avoid 
breathing vapour or mist. Provide adequate ventilation. Wear appropriate respirator 
when ventilation is inadequate. Put on appropriate personal protective equipment.
If specialised clothing is required to deal with the spillage, take note of any 
information in Section 8 on suitable and unsuitable materials. See also the 
information in "For non-emergency personnel".
:
Date of issue/Date of revision
:
26/03/2020
Version
:
3.12
19/02/2019
:
Date of previous issue