Instructions / Assembly

www.fernox.com
CENTRAL HEATING PROTECTOR F3
Physical Properties
Product Uses
Neutral universal cleaner for pre-commissioning new systems in accordance with BS7593:2006
Removes sludge, limescale and other debris to restore heating efficiency of existing systems
When used in conjunction with Protector F1 gas savings of up to 15% can be achieved
Compatible with all metals and materials commonly used in heating systems
Easy to use, system can be left running normally during cleaning
Suitable for use with all known powerflushing machines
pH Neutral, non-hazardous formula (COSHH rated zero)
One 1 pint bottle treats 26 gallons of water
Colour: Dark amber
Odour: Faint
Form: Liquid
pH (conc): 7.0 – 7.5
pH (0.5% soln) 7.5 – 7.8
SG: 1.20 @ 68°F
Fernox Cleaner F3 is a quick and effective pH neutral cleanser for central heating systems. It is
designed to remove all debris, sludge and scale from existing systems of all ages. In this way, it will
restore heating efficiency and eliminate or reduce boiler noise. It has also been designed for pre-
commission cleansing new installations in accordance with BS7593:1992, removing flux residues
and other debris, thereby helping extend the life of a system.
For older sludged systems, Cleaner F3 is particularly effective when used in conjunction with a
powerflushing unit. If the system is heavily scaled the use of Fernox Superconcentrate System
Cleaner is recommended. Cleaner F3 is a neutral, non-hazardous product that is well inhibited and
compatible with all metals and materials commonly used in heating systems.
For continued long term protection the system should be thoroughly cleansed and flushed in
accordance with BS7593:1992 and Benchmark using Fernox Cleaner F3, before treating with Fernox
Protector F1. We recommend Protector levels are checked regularly (annually).
V.001
Application
One 1 pint container of Cleaner F3 is usually sufficient to clean a typical domestic central heating system. Additional/repeat applications of
Cleaner F3 may be necessary for large systems, or if systems are heavily sludged.
First drain and refill the entire system with plain water. For optimum results the entire system, including drop feed radiators where fitted,
should be completely drainable. Preferably full bore gate valves with hose connectors should be provided temporarily for this purpose.
Motorized and thermostatically controlled valves must be set so that no part of the system is closed off during cleansing or rinsing.
Discharges must be made to the foul drain and not the surface water drain.
Fernox Cleaner F3
Size: 1 Pint
Code: 57882
26 GAL
10x