User's Manual

INTRODUCTION
The SK5-X/SK6-X is a universal keypad, can work as standalone keypad,
access controller or standard Wiegand output reader. It uses Atmel
MCU assuring stable performance. The operation is very user-friendly,
and low-power circuit makes it long service life.
The SK5-X/SK6-X supports 600 users, it support multi access modes
in either card access, PIN access, Card+PIN access, or multi cards/PINs
access, it can read 125KHz EM & HID for Low Frequency and 13,56MHz
Mifare for High Frequency tokens,cards and tags. Another advantage
of the SK5-X/SK6-X is it has extra features including block enrollment,
interlock, Wiegand 26~37 bits interface, 12~28V AC/DC voltage…etc.
Carton Inventory
Screw Driver
Master Cards
Master Add Card
Master Delete Card
Diode 1N4004 (For
relay circuit protection)
Self Tapping Screws
Wall Anchors
SK5-X/SK6-X
User Manual
Features
Waterproof, conforms to IP66
One relay, keyboard programmer
600 users
PIN length: 4~6 digits
Card type: 125KHz EM card, 125KHz HID card, 13.56MHz Mifare card
Wiegand 26~37 bits input & output
Can be used as Wiegand reader with LED & Buzzer output
Card block enrolment
Tri-colour LED status display
Pulse mode, Toggle mode
2 devices can be interlocked for 2 doors
Built in light dependent resistor (LDR) for anti tamper
Backlit keypad
Low temperature resistance(-40)
Wiring Connections
Environment
Operating Temperature
Operating Humidity
Relay output, exit button, alarm,
door contact, Wiegand input,
Wiegand output
Meets IP66
-40~60 (-40~140)
10%RH~ 98%RH
Physical
Zinc-Alloy Enclosure
Surface Finish
Dimensions
Unit Weight
Shipping Weight
Powder Coat
L150×W51×H23mm(SK6-X)
500g
650g
Wiegand Interface
Wiegand Input
Wiegand Ouput
User Capacity
Common Users
Panic Users
598
2
Operating Voltage
Idle Current
Active Current
12~28V AC/DC
< 65MA
< 100MA
Proximity Card Reader
Radio Technology
Read Range
HID & EM & Mifare
125KHz & 13.56MHz
2~6cm
PIN Output
Relay
Adjustable Relay Output Time
Lock Output Load
One (NO, NC, Common)
0~99 Seconds (5 seconds default)
2 Amp Maximum
INSTALLATION
Remove the back cover from the unit
Drill 2 holes(A,C) on the wall for the screws and one hole for the cable
Knock the supplied rubber bungs to the screw holes(A,C)
Fix the back cover rmly on the wall with 4 at head screws
Thread the cable through the cable hole(B)
Attach the unit to the back cover
Green
White
D 0
D 1
Grey
Brown
Wiegand Input/Output Data 0
Wiegand Input/Output Data 1
Negative contact for Alarm
Door/Gate Contact Input
(Normally Closed)
Alarm Output
Contact Input
Set Working Mode
1. Enter Program Mode
3. Exit Program Mode
(Master Code) #
8 1 #
*
8 0 # (Factory default)
*
Notes: the SK5-X/SK6-X has 3 working modes: Standalone Mode,
Controller Mode, Wiegand Reader Mode, choose the mode you use.
(Factory default is Standalone Mode / Controller Mode)
STANDALONE MODE
SK5-X/SK6-X can be worked as Standalone Reader for single door.
(Factory default mode)---8 0 #
Connection Diagram
Common Power Supply:
Access Control Power Supply:
Programming
Programming will vary depending on access conguration.
Follow the instructions according to your access conguration.
Set Relay Conguration
Programming Step Keystroke Combination
1. Enter Program Mode (Master Code) #
*
2. Pulse Mode 3 (1-99) # (factory default)
OR
The relay time is 1-99 seconds.
(1 is 50mS) (Default is 5 seconds)
Sets the relay to ON/OFF Toggle mode
2. Toggle Mode
3. Exit
*
3 0 #
The relay conguration sets the behaviour of the output relay on activation.
Set Access Mode
For Multi cards/ PINs access mode, the interval time of reading
cards/inputting PINs can not exceed 5 seconds, or else, the SK5-X/SK6-X
will exit to standby automatically.
1. Enter Program Mode
2. Card access
2. Card or PIN access
3. Exit
OR
2. Card+PIN access
OR
OR
(Master Code) #
*
4 0 #
4 1 #
*
4 2 # (Factory default)
4 3 (2~9) #
2. Multi cards/PINs access
(Only after reading 2~9 cards or PINs,
the door can be opened)
Door Detecting
Door Open Too Long (DOTL) warning: When used with an optional
magnetic contact or built-in magnetic contact of the lock, if the door
is opened normally, but not closed after 1 minute, the inside buzzer
will beep automatically to remind people to close the door and
continue for 1 minute before switching off automatically.
Door Forced Open warning: When used with an optional magnetic
contact or built-in magnetic contact of the lock, if the door is opened
by force, or if the door is opened after 60 seconds of the electro
-mechanical lock not closed properly, the inside buzzer and alarm
output will both operate. Enter Master code # or valid user
card /PIN to silence.
Users Operation & Reset to Factory Default
CONTROLLER MODE
SK5-X/SK6-X can work as Controller, connected with the external Wiegand
reader. (Factory default mode)---8 0#
Connection Diagram
- Open the door: Read valid user card or inputting valid user PIN
- Remove Alarm: Read valid user card or inputting valid user PIN,
or input Master Code #
- To reset to factory default & Add Master Cards: power off, press
the exit button, hold it and power on, there will be two beeps, and the
LED light turns into yellow, release the exit button, then read any two
cards(can be 125KHz EM card, 125KHz HID card or 13.56MHz Mifare
card, the LED will turn into red, means reset to factory default
st
successfully. Of the two cards reading, the 1 one is Master Add
nd
Card, the 2 one is the Master Delete Card.
Remarks:
If no Master Cards added, must press the Exit Button for at least
10 seconds before release.
Reset to factory default, the user's information is still retained.
Attention: Install a 1N4004 or equivalent diode is needed when use
a common power supply, or the reader might be damaged.
(1N4004 is included in the packing)
Set Master Code
1. Enter Program Mode
3. Exit Program Mode
(Master Code) #
*
#
0 (New Master Code) # (Repeat New Master Code)
2. Update Master Code
*
(Master code is any 6 digits)
ADVANCED APPLICATION
Interlock
Connection Diagram:
Remarks: The Door Contact must be installed and connected as
the diagram.
Let's name the two SK5-X/SK6-X Keypads as “A”and “B” for two
doors “1” and “2”
Step1:
Enroll the users on Keypad A and Keypad B
Step2:
Set both of the two readers (A and B) to Interlock function
1. Enter Program Mode
2. Interlocked-OFF
OR
(Master Code) #
*
9 0 # (factory default)
2. Interlocked-ON
3. Exit
*
9 1 #
The interlock operation is nished,
When and only door 2 is closed, the user can read the valid card or
input PIN on Reader A, door 1 will open; then when and only door
1 closed, read valid card or input PIN on Reader B, door 2 will open.
SK5-X/SK6-X
SK5-X/SK6-X
Attention:
Install a 1N4004 or equivalent diode is needed when use
a common power supply, or the keypad might be damaged.
(1N4004 is included in the packing)
Programming Step Keystroke Combination
1. Enter Program Mode (Master Code) #
*
Set Strike-out Alarm
The strike-out alarm will engage after 10 failed card/PIN attempts
(Factory default is OFF). It can be set to deny access for 10
minutes after engaging or disengage only after entering a
valid card/PIN or Master code.
1. Enter Program Mode
2. Strike-Out OFF
2. Strike-Out ON (Alarm)
3. Exit
OR
2. Strike-Out ON
OR
(Master Code) #
*
6 0 # (factory default)
6 1 # Access will be denied for 10 minutes
*
6 2 #
Set Audible and Visual Response
1. Enter Program Mode
2. Control Sounds
2. Control Keypad Backlit
3. Exit
OR
2. Control LED
OR
(Master Code) #
*
OFF = 7 0 #
*
OFF = 7 2 #
OFF = 7 4 #
ON = 7 1 #
ON = 7 3 #
ON = 7 5 #
(factory defaults are ON)
Master Cards Usage
Using Master Cards to add and delete card / PIN users
Add a User
1. (Read Master Add Card)
2. (Read User Card)
Repeat Step 2 for additional user cards
3. (Read Master Add Card)
Delete a User
1. (Read Master Delete Card)
2. (Read User Card)
Repeat Step 2 for additional user cards
3. (Read Master Delete Card)
2. To disable door open detection 5 0 # (factory default)
OR
5 1 #
3. Exit
*
2. To enable door open detection
WIEGAND READER MODE
SK5-X/SK6-X can work as Standard Wiegand Reader, connected to
the third party Controller--- 8 1 #
Connection Diagram
Keypad Reader
Set Wiegand Output Formats
Please set the Wiegand output formats according to the Wiegand
input format of the controller.
Note:
-Yellow wire: Buzeer control
If you need to connect Brown/Yellow wires:
When the input voltage for LED is low, the LED will turn into
Green; and when the input voltage for Buzzer is low, it will sound.
-Brown wire: Green LED light control
When set into Wiegand Reader mode, nearly all settings in
Controller Model will become invalid. And Brown & Yellow
wires will be redened
as below:
1. Enter Program Mode
2. Wiegand output bits
3. Exit
(Master Code) #
*
8 (26~37) # (factory default is 26bits)
8 (4 or 8 or 10) # (Factory default is 4bits)
*
PIN output bits
Add PIN Users:
To add PIN users, after enter into programming mode on SK5-X/SK6-X,
PIN(s) can be input/ added on either SK5-X/SK6-X controller or the external
Keypad Reader.
Delete PIN Users:
the same way as add users.
CONTENTS
WIEGAND
READER MODE
13
5
STANDALONE
MODE
ADVANCED
APPLICATION
15
11
CONTROLLER
MODE
1
INTRODUCTION
3
INSTALLATION
Operation Status LED Buzzer
Enter into programming mode
In the programming mode
Operation error
Exit from the programming mode
Open lock
Red light shines
Orange light bright
-
Red light bright
Green light bright
Alarm
Red light Shines quickly
Stand by Red light bright
-
One beep
One beep
Three beeps
One beep
One beep
Beeps
Basic Congure
Enter Program Mode
Exit Program Mode
(Master Code) #
(Factory default is 123456)
*
*
Sound and Light Indication
Door Bell Connect (for SK6-X only)
Door
Bell
Brown & Black
Yellow & Black
Power +
Power
_
Door Bell B
Door Bell A
Power
Programming
- Basic Programming is the same as Standalone Mode
- There are some exceptions for your attention:
SK5-X/SK6-X Connected with External Card Reader:
If EM card reader or HID card reader: users can be added/deleted
on either SK5-X/SK6-X or external reader.
If Mifare reader: users can only be added/deleted on external reader.
SK5-X/SK6-X Connected with Fingerprint Reader:
For example:
Connect F2 as the ngerprint reader to SK5-X/SK6-X, it is of two
steps to enroll the valid ngerprint.
Step 1: Add the Fingerprint (A) on F2
Step 2: Add the same Fingerprint(A) on SK5-X/SK6-X:
Enter Program Mode:
2.
OR
(Master Code) #
*
1 (Press Fingerprint A once on F2) # (ID auto allocated)
2.
3.
1 (User ID) # (Press Fingerprint A on F2) # (Select specic ID)
Exit:
*
Remarks: 4 means 4 bits, 8 means 8 bits, 10 means 10 digits virtual
number.
1. Enter Program Mode
2.PIN input bits
3. Exit
(Master Code) #
*
8 (4 or 8 or 10) #
(factory default is 4bits)
*
SK5-X/SK6-X Connected with Keypad Reader:
SK5-X/SK6-X Connected with Keypad Reader:
The keypad reader can be 4 Bits, 8 Bits (ASCII), or 10 Bits output
format. Choose the below operation according to the PIN output
format of your reader.
Set Wiegand Input Formats
Please set the Wiegand input formats according to the Wiegand
output format of the external Reader.
1. Enter Program Mode
3. Exit
(Master Code) #
*
*
2. Wiegand input bits
8 (26~37) # (factory default is 26bits)
1.
Specications
Brown & Black
(SK6-X)
Yellow & Black
(SK6-X)
Contact for Door Bell
Contact for Door Bell
Door Bell A
Door Bell B
600
Yellow
OPEN
Request to Exit(REX) Input
White & Black
Relay Common
Common Connection for Relay
Output
Green & Black
Relay NC
Normally Closed Relay Output
Wiring
Wire Color
Function Notes
Red
AC&DC
12-28V AC/DC Power Input
Blue
Relay NO
Normally Open Relay Output
Black
GND
Negative Pole
Advanced Input and Output Features
Pass-Through Wiring (Wiegand Reader or Controller)
Keystroke CombinationProgramming Step
Keystroke CombinationProgramming Step
2. Standalone/Controller Mode
OR
2. Wiegand Reader Mode
Keystroke Combination
Programming Step
Notes:
User ID number: Assign a user ID to the access card / PIN in order to
track it. The common user ID number can be any number from 1~598, the
panic user ID is from 599~600. IMPORTANT: User ID is do not have to be
proceeded with any leading zeros. Recording of User ID is critical.
Modications to the user require the User ID be available.
Proximity Card: Any 125KHz industry standard 26 bits HID and
EM cards and 13.56MHz Mifare card.
PIN: Can be any 4~6 digits except 8888 which is reserved.
Add Panic Users
Add Common Users
1. Enter Program Mode
(Master Code) #
*
Add Card User
2. Add Card: Using Auto ID 1 (Read Card) #
(Allows SK5-X/SK6-X to assign Card
to next
available User ID number)
OR
The cards can be added continuously.
1 (User ID) # (Read Card) #
(User ID is any number from 1-598)
2. Add Card: Select Specic ID
(Allows Master to dene a specic
User ID to associate the card to)
OR
2. Add Card: by Card Number
OR
2. Add Card: Block Enrolment
(Allows Master to add up to 598 card
to the Reader in a single step)
Takes 2 minutes to program.
1 (Input 8/10 digits Card number) #
1 (User ID) # (Card quantity) # (The
rst card number) #
Add PIN User
1 (PIN) #
The PINs can be added continuously.
2. Add PIN: Using Auto ID
(Allows SK5-X/SK6-X to assign PIN
to next
available User ID number)
1 (User ID) # (PIN) #
The user ID is any number from 1-598
2. Add PIN: Select Specic ID
(Allows Manager to dene a specic
User ID to associate the PIN to)
(PIN: 4~6 digits)
3. Exit
*
Cards’ number must be consecutive;
Card quantity=number of cards to be
enrolled.
Keystroke CombinationProgramming Step
1. Enter Program Mode (Master Code) #
*
2. Add Card: 1 (User ID) # (Read Card / Input 8/10
OR
digits Card number) #
(User ID is any number from 599~600)
2. Add PIN:
3. Exit
*
1 (User ID) # (PIN) #
Change PIN Users
Note: Below is done outside programming mode, users can undertake
this themselves
1. Change PIN: By Card (Read Card) (Old PIN) # (New PIN) #
PIN(8888) to cards when adding)
(Repeat New PIN) #
(Repeat New PIN) #
2. Change PIN: By PIN
3. Exit
*
(There will auto allocate
*
(User ID) # (Old PIN) # (New PIN) #
*
Delete Users
1. Enter Program Mode (Master Code) #
*
Delete Common Card User
2. Delete Card - By Card 2 (Read Card) #
OR
2. Delete Card - By ID number
OR
The cards can be deleted continuously.
2 (Input 8/10 digits Card number) #
2.Delete User - By Card number
2 (User ID) #
Delete Common PIN User
2.Delete PIN - By PIN 2 (Input PIN) #
OR
2.Delete PIN - By ID number
2 (User ID) #
Delete Panic User
Delete All Users
2.Delete Panic Card User 2 (User ID) #
OR
2.Delete Panic PIN User
2 (User ID) #
3. Exit
*
2. Delete All Users
2 (Master Code) #
Keystroke CombinationProgramming Step
Programming Step Keystroke Combination
Keystroke CombinationProgramming Step
Keystroke CombinationProgramming Step
Keystroke CombinationProgramming Step
Keystroke CombinationProgramming Step
Keystroke CombinationProgramming Step
Keystroke CombinationProgramming Step
Keystroke CombinationProgramming Step
Keystroke CombinationProgramming Step
Basic Standalone Wiring
70mm
53mm
123mm
Grey & Black
AC&DC
12-28V AC/DC Power Input
-
-
+
+
-
+
D0
D1
ALARM-
OPEN
D_IN
GND
AC&DC
AC&DC
NC
COM
NO
Green
White
Grey
Yellow
Brown
Red
Grey & Black
Blue
White & Black
Green & Black
Black
D0
D1
DC /3A12V
Door
detecting switch
Special Power Supply
Alarm
NC COM NO
+12V
GND
V+
GND
OPEN
Exit button
Wiegand reader
Fail-Safe lock
Fail-Secure lock
SK5-X/SK6-X
Green & Black
AC&DC
Grey & Black
White & Black
AC&DC
AC&DC
AC&DC
Green & Black
Grey & Black
White & Black
Power
Exit Button
_
+
Fail-Safe Lock: NC
Fail-Secure Lock: NO
Power "+"
1n4004
Lock
Door
detecting switch
Power "+"
Alarm "-"
Alarm "-"
Alarm
_
+
12-28V AC/DC
D0
D1
ALARM-
OPEN
D_IN
GND
AC&DC
AC&DC
NC
COM
NO
Green
White
Grey
Yellow
Brown
Red
Grey & Black
Blue
White & Black
Green & Black
Black
SK5-X/SK6-X
Exit Button
Door
detecting switch
SK5-X/SK6-X
Alarm "-"
Alarm "-"
Alarm
_
+
Power
GND
NOCOM
NC
+12V
DC 12V/3A
_
+
_
+
Fail-Secure lock
Fail-Safe lock
PUSH
D0
D1
ALARM-
OPEN
D_IN
GND
AC&DC
AC&DC
NC
COM
NO
Green
White
Grey
Yellow
Brown
Red
Grey & Black
Blue
White & Black
Green & Black
Black
SK5-X/SK6-X Simplied Instruction
Operation
0 - New Code - # - Repeat the New Code - #
(code: 6 digits)
1 - Read Card - #
(can add Card continuously)
1 - PIN - #
2 - Read Card - # for Card user
2 - PIN - # for PIN user
Exit From the Programming
Mode
Function Description
Enter the Programming Mode
Change the Master Code
Add Card User
Add PIN User
Delete User
How to be granted access
Card User
PIN User
Read card
Input PIN #
- 123456 - #
then you can do the programming
(123456 is the factory default master code)
(PIN Length: 4~6 digits)
1 2
43
5 6
87
9
*
0
#
Access Controller/Reader
SK5-X
SK6-X
L148xW56xH22.5mm(SK5-X)
1 2
43
5 6
87
9
*
0
#
The SK5-X/SK6-X supports the Interlock funciton. It is of two keypads
for two doors, and mainly used for banks, prisons, and other places
where a higher level security is required.
OR
Wiegand 26~37 bits
26~37bits (default: 26bits)
26~37bits (default: 26bits)
4bits, 8bits(ASCII), 10 digits Virtual
Number (default: 4bits)
+
1
2
~2
8
V

Summary of content (2 pages)