Installation Instructions
Table Of Contents
Page 12
3.2.2 Block Panel
BLOCK: Block number, between 001 and 999 (default option 1).
DEVICE NO.: Panel Number, between:01-99 (default option 1).
TYPE: For block entrance, choose BLOCK PANEL. The panel can communicate with all
devices on the same block.
LANGUAGE: Select the desired language for the drop-down options. (default option ENGLISH).
Refresh the webpage after change the language.
INFORMATION: 9901 GUARD UNIT, Prompt information to be displayed on the panel, between
9901-9998, default option 9901. It is possible to modify the number according to the Guard Unit
that each panel will call.
PANEL VOLUME: Select the desired value between 1 and 5, (default option 4).
The conversation volume is common for uplink and downlink.
DOOR OPEN VOICE: Open door voice prompt can be enabled or disabled. The default is
enabled.
VIDEO RESOLUTION: In order to fit the different type of Monitor, The default values 640×480
is be used usually.
SIP DIVERT MODE: (this feature may not be available at the time of releasing the manual)
PARALLEL CALL: When the panel calls the resident, the monitor and the call divert APP ring
at the same time. Once one terminal answers the call the other one stops ringing.
SEQUENTIAL CALL: When the panel calls the resident, the monitor will ring about 30s if no