Certifications 2

COMPILE REPORT OF MSDS
REPORT No. : CNB3170831-02998-CO
DATE : Sep. 12, 2017
PAGE : 4 of 10
The measurement results only apply to the submitted samples.
Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.
CTS (Ningbo) Testing Service Technology Co., Ltd.
Fl.1 & 8 West, Bldg. B, No. 66, Qingyi Rd.,Hi-Tech Zone, Ningbo, Zhejiang, China
Tel+86-574-87912121 (16 lines) Fax+86-574-87907993
Complaint line+86-574-87908003 E-mailcts@cts-lab.com See Reverse For Terms And Conditions of Service
2.2 Results
MSDS (Material Safety Data Sheet)
1 Identification of the substance / Preparation and of the company
PRODUCT NAME : Solder wire
PRODUCT TYPE : /
Manufacturer/Supplier : Ningbo welding material factory
ADDRESS : Meilin, Zhuangqiao, Ningbo
TEL : /
FAX : /
E-mail : /
2 HAZARDS IDENTIFICATION
· 2.1 Classification of the substance or mixture
· Classification according to Regulation (EC) No 1272/2008.
The product is not classified according to the CLP regulation.
· 2.2 Label elements
· Labelling according to Regulation (EC) No 1272/2008 Void
· Hazard pictograms Void
· Signal word Void
· Hazard statements Void
· 2.3 Emergency overview
This product consists of silver grey metal wire which contains core of rosin. There is no
immediate health hazard associated with the wire product and it is not reactive under normal
circumstances of use. Though the wire is not flammable, if involved in a fire and exposed to
extremely high temperatures, harmful fumes of metal oxides may be generated.
During soldering operations, the most significant routes of exposure are inhalation, and contact
of the skin and eyes. Molten solder can cause thermal burns. Prolonged or repeated exposure to
tin fumes can result in benign pneumoconiosis, which causes inflammation of the lungs, but
there is no distinct fibrosis or evidence of disability.
· 2.4 Potential health effects information
Inhalation: The fumes generated during soldering operations may cause respiratory irritation.
Ingestion: Ingestion is not expected to occur in normal use.
Eye Contact: Contact with the wire form of this product can be physically damaging to the eye.
Contact with the molten core solder will cause burn to the eyes. Fumes generated during
soldering operations can be irritating to the eyes.
Skin Contact: Contact of the wire form of this product with skin is not anticipated to be irritating.
Contact with the molten core solder will burn contaminated skin. Fumes generated during
soldering operations can be irritating to the skin.