Service Manual
Table Of Contents
- 627333-A
- 01 Introduction
- Safety
- Follow Safety Instructions
- Prepare for Emergencies
- Safety Alert Symbol
- Signal Words
- Informational Messages
- Important Safety Information
- General Hazard Information
- Emergency Exit From Cab
- Operating The Vehicle Safely
- Prevent Vehicle Runaway
- Use Safety Lights and Devices
- Operating On Slopes
- Traveling On Public Roads
- Stopping And Parking The Vehicle
- System Boom Safety
- Avoid Eye Contact With Radar
- Exhaust Fumes
- Overhead Electrical Power Lines
- Noise
- Handle Fuel Safely - Avoid Fires
- Stay Clear Of Rotating Drive Lines And Moving Parts
- Towing Other Vehicles / Trailers / Equipment
- Modifications
- Maintenance And Service Safety
- Practice Safe Maintenance
- Chemical Safety
- Wear Protective Clothing
- Work In A Clean Area
- Understand Correct Service
- Use Proper Tools
- Support Machine Properly
- Proper Lifting Equipment
- High-Pressure Fluids
- Hydraulic Hoses
- Avoid Heating Near Pressurized Fluid Lines
- Service Cooling System Safely
- Remove Paint Before Welding Or Heating
- Batteries
- Tires And Wheels
- Dispose Of Waste Properly
- Mobile Radio Installations
- Maintenance In The Articulation Joint (Hinge) Area
- Safety Tread and Grip Material
- Safety And Service Decal Locations Chassis
- Safety And Service Decal Locations Cabine
- General
- Dimensions
- Torque Specifications
- Jack Up The Machine
- Tooling list
- Index
- Safety
- 02 Engine
- 03 Powertrain
- Transmission Service Manual
- Transmission and Solenoids
- Testing and Adjusting
- Transmission Troubleshooting
- Disassembly and Assembly
- Drive line
- Index
- TA19 KENR6054-00
- TA19 KENR6678 (Modification)
- 04 Chassis
- MM9L(Modification)
- 05 Cab
- Cab
- Cab Seat
- HVAC
- General Information
- Theory of operation
- Basics of Refrigeration
- Air Conditioning Process
- HVAC System
- Automatic Temperature Control
- Refrigerant Relief Valve
- Temperature Sensors
- Evaporator Coil
- Heater Core (Cab)
- Actuator Motor (Water Valve)
- AirFlow
- Motor (Air Conditioning Blower)
- Speed Control
- Actuator Motor (Damper)
- Glossary of Terms
- HVAC Specification
- HVAC Testing and Adjusting
- Troubleshooting Machine Preparation
- General Troubleshooting Information
- Visual Inspection
- Troubleshooting Faults With Service Codes (Active)
- Troubleshooting Air Conditioner Control
- Problem List
- Probable Causes
- No Display
- Probable Solution
- No Blower Fan
- Probable solution
- No Heat
- Probable Solution
- No Cooling
- Probable Solution
- System is putting out cool air when heat needed
- Probable Solutions
- System is putting out hot air when cooling needed.
- Probable Solution
- No Fan or Erratic Fan
- Probable Solutions
- Nothing Works
- Probable Solution
- Electric Actuator for Mode of Airflow is not Moving or Working Properly
- Probable Solutions
- Refrigerant Compressor Oil - Check
- Refrigerant System - Charge
- Complete Charge of System from a Refrigerant Tank with a Scale
- Adding Additional Refrigerant to an Air Conditioning System with Low Charge
- Manifold Gauge Set (Refrigerant) - Remove
- Control Panel - Test
- Index
- 06 Electrical
- 07 Hydraulic
- 08 Air System
KENR6054 51
Disassembly and Assembly S ec tio n
i02649606
Modulating Valve
(Transmission Clutch) -
Remove and Install
SMCS Code: 3139-010-T3
Removal Procedure
NOTICE
Care must b e taken to ensure that fluids are contained
during performance of inspection, maintenance, test-
ing, adjusting and repair of the product. Be prepared to
collect the fluid with suitable containers before open-
ing any compartment or disassembling any compo-
nent containing fluids.
Refer to Special Publication, NENG2500, “Caterpillar
Dealer Service Tool Catalog” for tools and supplies
suitable to collect and contain fluid s on Caterpillar
products.
Dispose of all fluids according to local regulations and
mandates.
Note: Put identification marks on all lines, on all
hoses, on all wires, and on all tubes for installation
purposes. Plug all lines, hoses, and tubes. This
helps to prevent fluid loss and this helps to keep
contaminants from entering the system.
g013301
12
Illustration 209
1. Disconnect harness assembly (1).
2. Remove b
olts (2) and remove modulating control
valve (3).
3. Remove O
-ring seal (4).
g01265571
Illustrati
on 210
4. Remove nut (5) and washer (6).
5. R em ove coil assembly (7).
6. Remove cart
ridge (8) and remove O-ring seal (9).
7. Repeat steps 1 through 6 for the remaining valves.
Installation Procedure
g01265571
Illustration 211
1. Lubricate O-ring seal (9) with lubricant that is
being sealed. Install O-ring seal (9).
2. I nstall cartridge (8). Tighten cartridg e (8) to a
torque of 50 ± 5 N·m (37 ± 4 lb ft).
3. Ins tall coil assembly (7).