Operating Manual
Table Of Contents
- OPERATING MANUAL
- NUMERICAL INDEX
- SAFETY INSTRUCTIONS
- OPERATION
- 1. Driver seat
- 2. Display instruments and operating controls
- 3. Heating and ventilation
- 4. Rearwiew mirror
- 5. Start-up
- 6. Starting and stopping the engine
- 7. Vario transmission
- 8. Fuel consumption measurement
- 9. Tractor Management System (TMS)
- 10. PTO
- 11. Four wheel drive (4-WD)
- 12. Differential lock
- 13. Front axle suspension
- 14. Power lift and PTO automatic mode
- 15. Brakes
- 16. Steering
- 17. Hydraulics
- 18. Electronic lifting gear control, rear
- 19. Three-point link
- 20. Front power lift
- 21. Trailing devices
- 22. Compressed air system
- 23. Additional ballasting
- 24. Track adjustment
- 25. Twin tyres
- 26. On-board computer
- 27. Computer
- 28. Storing the settings
- 29. Implement control
- 30. Variotronic Ti
- CARE AND MAINTENANCE
- 1. General
- 2. Opening the bonnet
- 3. Engine oil change
- 4. Fuel system
- 5. Dry air .lter
- 6. Cooling system
- 7. V belt
- 8. Brake and clutch system
- 9. Front PTO
- 10. Transmission and axle drives
- 11. Four-wheel drive axle
- 12. Power lift
- 13. Hydraulic system
- 14. Steering
- 15. Front wheels
- 16. Heating and ventilation
- 17. Air conditioning
- 18. Windshield washer system
- 19. Cleaning the tractor
- 20. Electrical and electronic systems
- 21. Fuses
- 22. Wiring diagrams
- IMPLEMENTS
- FAULTS AND REMEDIAL ACTIONS
- TECHNICAL DATA
- ALPHABETICAL INDEX
- Important information on service and maintenance
70
OPERATION
17.6 Setting the valves
Text-module
The following settings can be made:
ETNum-list
Opening the valve setting submenu
Operation_Pic_number:1
● Press key (F3). The following valve setting
submenu appears.
Operation_Pic_number:1
This window gives an overview of the individual
valve settings.
Text-module
● Indicator bars (A), lifting flow rate.
● Indicator bars (B), lowering flow rate.
● Indicator bars (C), activation period.
● Lock symbol (D), valve locking ON/OFF.
● Clock symbol (E), is displayed while the rele-
vant valve is activated by the time function.
● Cylinder symbol (F), is displayed while the re-
levant valve is activated in the floating posi-
tion.
● Valve prioritisation (H) appears if a valve is
prioritised.
● Keys (F1 - F4), for changing to the sub-menu
of individual valves.
1.Flow rate
2.Timer
3.Floating position
4.Valve locking
Fig.129
Fig.130
Example:
● Press key (F1). The following submenu appe-
ars.
Operation_Pic_number:1
● Use the ESC key to exit this submenu and se-
lect a different valve.
Setting the flow rate for lifting/lowe-
ring
(Setting range between 1-80 l/min).
Operation_Pic_number:1
Bar indicator (A), lifting.
Bar indicator (B), lowering.
● Set the flow rate for lifting with rotary switch
(P1), and for lowering with rotary switch (P2).
NOTE:
If only the bar indicator (A, B) changes and
the indicator (D) remains unchanged, the hy-
draulics are undersupplied. Increase engine
speed.
Fig.131
Fig.132