Operating Manual
Table Of Contents
- OPERATING MANUAL
- NUMERICAL INDEX
- SAFETY INSTRUCTIONS
- OPERATION
- 1. Driver seat
- 2. Display instruments and operating controls
- 3. Heating and ventilation
- 4. Rearwiew mirror
- 5. Start-up
- 6. Starting and stopping the engine
- 7. Vario transmission
- 8. Fuel consumption measurement
- 9. Tractor Management System (TMS)
- 10. PTO
- 11. Four wheel drive (4-WD)
- 12. Differential lock
- 13. Front axle suspension
- 14. Power lift and PTO automatic mode
- 15. Brakes
- 16. Steering
- 17. Hydraulics
- 18. Electronic lifting gear control, rear
- 19. Three-point link
- 20. Front power lift
- 21. Trailing devices
- 22. Compressed air system
- 23. Additional ballasting
- 24. Track adjustment
- 25. Twin tyres
- 26. On-board computer
- 27. Computer
- 28. Storing the settings
- 29. Implement control
- 30. Variotronic Ti
- CARE AND MAINTENANCE
- 1. General
- 2. Opening the bonnet
- 3. Engine oil change
- 4. Fuel system
- 5. Dry air .lter
- 6. Cooling system
- 7. V belt
- 8. Brake and clutch system
- 9. Front PTO
- 10. Transmission and axle drives
- 11. Four-wheel drive axle
- 12. Power lift
- 13. Hydraulic system
- 14. Steering
- 15. Front wheels
- 16. Heating and ventilation
- 17. Air conditioning
- 18. Windshield washer system
- 19. Cleaning the tractor
- 20. Electrical and electronic systems
- 21. Fuses
- 22. Wiring diagrams
- IMPLEMENTS
- FAULTS AND REMEDIAL ACTIONS
- TECHNICAL DATA
- ALPHABETICAL INDEX
- Important information on service and maintenance
228
FAULTS AND REMEDIAL ACTIONS
4. Flame starting system faults
The flame starting system control unit detects faults in the flame starting system, and indicates these
with flash codes on the preheating indicator lamp.
The flashing duration is about 60 secs.
Operation_Pic_number:1
Text-module
The following faults are detected:
Fault code A:
● Break in the flame glow plug element loop or its supply line.
Fault code B:
● Faulty fuse for the flame start control unit or no supply voltage (B+).
Fault code C:
● Break in the solenoid valve line or coil.
In all cases, only the indicator lamp flashes. Solenoid valve and flame heater plug remain switched off.
Fig.5