B
OVERALL SYSTEM/TRACTOR
Fault code table COM III
400 .. 1001- 724 .. 1001- 731 .. 1001-
401 .. 1001- 725 .. 1001-
402 .. 1001- 726 .. 1001-
403 .. 1001- 727 .. 1001-
404 .. 1001- 729 .. 1001-
0000 B T000434
Version 1
20/09/2007
34
Crop_this_page
8.3.28 A004 - ECU, control panel Fault in rear EPC quick lift
switch
"Raise" and "Lower"
only possible via ex-
ternal buttons.
Wiring diagram
Sheet 25
REAR EPC
ACTUATION/STATUS
8.3.31 B031 - Sensor, right draught sens-
ing pin
Signal line fault
Sensor faulty
Supply of 10.0 V from A014
faulty
Limited performance
during traction con-
trol
Wiring diagram
Sheet 25
REAR EPC
DRAUGHT SENSING PIN
8.3.32 B032 - Sensor, left draught sensing
pin
Signal line fault
Sensor faulty
Supply of 10.0 V from A014
faulty
Limited performance
during traction con-
trol
Wiring diagram
Sheet 25
REAR EPC
DRAUGHT SENSING PIN
8.3.33 A014 - ECU, EPC OBE
G001 - Battery 1 (12 VDC)
Battery voltage < 11.0 V Control barred and
locked
Wiring
diagram
Sheet 25
8.3.40 A004 - ECU, control panel
Rear power lift quick lift switch
Switch faulty Raising and lowering
only via external con-
trols
Wiring diagram
Sheet 25
REAR EPC
ACTUATION/STATUS
CAN (K bus) fault A004/A014
8.3.41 A004 - ECU, control panel
Rear power lift quick entry button
Faulty button Quick entry not func-
tioning
Wiring diagram
Sheet 25
REAR EPC
ACTUATION/STATUS
CAN (K bus) fault A004/A014
8.3.42 A004 - ECU, control panel
Rear EPC, hitch function
Faulty button Hitch function not op-
erational
Wiring diagram
Sheet 25
REAR EPC
ACTUATION/STATUS
CAN (K bus) fault A004/A014
8.3.43 A004 - ECU, control panel
Automatic function (switching from
control panel to joystick)
Faulty button Switching not possi-
ble
Wiring diagram
Sheet 25
REAR EPC
ACTUATION/STATUS
CAN (K bus) fault A004/A014
Fault
code
DIN brief description Cause Consequences Reference FENDIAS / Note