Crop_this_page
4.1.E2 A002 - ECU, enhanced control Pressure regulator control pa-
rameters in tractive power
control not plausible (B008/
B039) or read incorrectly.
EOL programming
4.1.E3 A002 - ECU, enhanced control Checksum error, parameter
for throttle pedal mode
TMS is switched off EOL programming
4.1.E4 A002 - ECU, enhanced control Checksum error for active
hold function parameters
EOL programming
4.1.E5 A002 - ECU, enhanced control Checksum error for range
control parameters
EOL programming
4.1.E6 A002 - ECU, enhanced control Checksum error for load limit
control parameters
EOL programming
4.1.E7 A002 - ECU, enhanced control Checksum error for joystick
parameters
EOL programming
4.1.E8 "Neumaier reversing system" equip-
ment
Checksum error in clutch ped-
al potentiometer on Neumaier
reversing system, or clutch
calibration faulty
(Neumaier service manual)
Calibration code "4011"
4.1.E9 A002 - ECU, enhanced control Values for shift from range II
to I outside tolerance
Shifting only possible
when stationary
Calibration code "4003"
4.1.EA A002 - ECU, enhanced control Internal fault (RAM/EEPROM) Continuation in emer-
gency mode possible
EOL programming
4.1.EB B016 - Sensor, travel range detec-
tion
No calibration or drifted, al-
tered values
Continuation in emer-
gency mode possible
TRANSMISSION
TRAVEL RANGE
Calibration code "4003"
4.1.EC B055 - Sensor, foot throttle No calibration or drifted, al-
tered values
Continuation in emer-
gency mode possible
TRANSMISSION, LOAD LIM-
IT CONTROL, calibration code
"4005"
Fault
code
DIN brief description Cause Consequences Reference FENDIAS / Note