User Manual

FENDT 400 Vario COM III, FENDT 700 Vario COM III, FENDT 800 Vario COM III Faults
B
OVERALL SYSTEM/TRACTOR
Fault code table COM III
400 .. 1001- 724 .. 1001- 731 .. 1001-
401 .. 1001- 725 .. 1001-
402 .. 1001- 726 .. 1001-
403 .. 1001- 727 .. 1001-
404 .. 1001- 729 .. 1001-
0000 B T000434
Version 1
20/09/2007
22
Crop_this_page
4.1.A5 A009 - Actuator unit Initial reference (=zero posi-
tion) could not be found dur-
ing ignition ON
Continuation in emer-
gency mode possible
TRANSMISSION
TRANSMISSION ADJUST-
MENT
4.1.A6 A009 - Actuator unit Reference point signal fault
during operation
Continuation in emer-
gency mode possible
TRANSMISSION
TRANSMISSION ADJUST-
MENT
4.1.B0 All bus users Initialisation error Restricted CAN bus
data communication
Check CAN bus,
Chapter 9000 Reg. E
EOL programming
4.1.B2 A002 - ECU, enhanced control Fault in EPROM programming
(travel range selector I/II)
Range cannot be
changed while driv-
ing.
EOL programming
4.1.B3 A002 - ECU, enhanced control Fault in EPROM programming
(quick reverse rate parame-
ters)
Quick reversing pos-
sible with standard
values.
EOL programming
4.1.B4 B010 - Sensor, engine speed Input parameter values for
plausibility monitoring are in-
correct.
Standard parameters
are stored, plausibility
monitoring system
remains functional.
EOL programming
4.1.B5 A002 - ECU, enhanced control Checksum error rate parame-
ters, quick reverse for Tractor
Management System (TMS)
EOL programming
4.1.B6 "Neumaier reversing system" equip-
ment
Neumaier reversing system
control failed or faulty
(Neumaier service manual)
4.1.E0 Y004 - Solenoid valve, turbo-clutch Wrong characteristic stored Continuation in emer-
gency mode possible
Calibration code "4009"
4.1.E1 A002 - ECU, enhanced control Pressure regulator control pa-
rameters in tractive power
control (ML transmission ad-
justment) not plausible or
read incorrectly
EOL programming
Fault
code
DIN brief description Cause Consequences Reference FENDIAS / Note