User Manual

all Vario tractors
Tractor / General system
Vario Tractors - Fault Codes
B
Faults
12/1999
0000 000001
B
f
2/58
Capitel Docu-No.Index
Date Version
Page
Vario Tractors - Fault Codes
0.0.1A A002,
Y015,
Y016,
Y017,
Y018,
Y019
ECU, enhanced control,
electric auxiliary control
valves
Bus fault No functions available,
no display
Power supply for CAN
bus is in circuit board
A013; fuses F040, F041
0.0.1B A002 ECU, enhanced control TeachIn bus faulty -
Master (Variotronic TI)
('Teach-in data transfer
fault')
Emergency mode
0.0.1E ECU, Neumaier Bus fault Neumaier
reversing system
Neumaier System
doesn't work
(Neumaier Service
Manual)
0.0.1F A034 Joystick Joystick bus fault ('Drive
switch data transfer
fault')
Emergency operation,
no auxiliary valve
operation
Power supply for CAN
bus is in circuit board
A013; fuse F047
JOYSTICK CAN -
JOYSTICK
0.0.20 A007 Instrument cluster CAN Bus fault between
A007 instrument cluster
and tractor electronics
No functions available,
no display
Power supply for CAN
bus is in circuit board
A013; fuses F040, F041
0.1.50 A007 Instrument cluster VDO instrument cluster
EEPROM not
programmed
Malfunctions in
instrument cluster
EOL reprogramming
necessary
0.1.51 B012 Engine oil pressure
sensor
Sensor fault, wiring fault No monitoring 'Instrument cluster'
circuit diagram
12 V supply fault A013 fuse 24
0.1.54 B019 Compressed air tank
pressure sensor
Sensor fault, wiring fault No display 'Instrument cluster'
circuit diagram
12 V supply fault A013 fuse 25
0.1.55 S036 Hydraulic oil level
sensor
Sensor fault, wiring fault No monitoring 'Spool valves 1' circuit
diagram
0.1.56 B005,
A021,
A022
Temperature sensor
engine temp. (=water),
(ECU,EDC / EMR)
Sensor fault, wiring fault No monitoring 'Instrument cluster'
circuit diagram
Fault
code
Id code Brief description Description Consequences Link FENDIAS / Note