User Manual
Table Of Contents
all Vario tractors
Tractor / General system
Vario Tractors - Fault Codes
B
Faults
12/1999
0000 000001
B
f
53/58
Capitel Docu-No.
Index
Date Version
Page
Vario Tractors - Fault Codes
A.1.4F Y018 Spool valve fault, valve 4 Setpoint message is
missing or not plausible
Valve moves into neutral
position
ELECTRICAL VALVES
VALVE 4 / VENDI
Configuration message
is missing or not
plausible
Potentiometer or PWM
fault
A.1.A0 A002 E-box EEPROM fault while
storing
A.1.A1 A002 E-box EEPROM fault while
loading
A.1.A2 More valves connected
than registered via
end-of-line
programming. Program.
Not all valves can be
operated
A.1.B0 A003,
A034
Crossgate lever Not calibrated Valves cannot be
operated
Calibration code '1001'
A.1.B1 A003,
A034
Crossgate lever X-axis signal fault Valves cannot be
operated
'Spool valves 1' circuit
diagram
SPOOL VALVES
OPERATION
A.1.B2 A003,
A034
Crossgate lever Y-axis signal fault Valves cannot be
operated
'Spool valves 1' circuit
diagram
SPOOL VALVES
OPERATION
A.1.B3 A003,
A034
Crossgate lever X and Y axis signal fault;
crossgate lever missing
Valves cannot be
operated
'Spool valves 1' circuit
diagram
SPOOL VALVES
OPERATION
A.1.B4 A003,
A034
Crossgate lever Zero position signals of
X- and Y-axes are not
identical to the 'Rest
position' signal
(=plausibility check)
Valves cannot be
operated
'Spool valves 1' circuit
diagram
SPOOL VALVES
OPERATION
A.1.B5 A003,
A034
Crossgate lever 'Rest position' signal
fault
Valves cannot be
operated
'Spool valves 1' circuit
diagram
SPOOL VALVES
OPERATION
A.1.C0 A004 Control console Not available or bus not
connected
Fault
code
Id code Brief description Description Consequences Link FENDIAS / Note