User Manual
Table Of Contents
all Vario tractors
Tractor / General system
Vario Tractors - Fault Codes
B
Faults
12/1999
0000 000001
B
f
51/58
Capitel Docu-No.
Index
Date Version
Page
Vario Tractors - Fault Codes
A.1.35 Y017 Spool valve fault, valve 3 Overvoltage (> 45 volts) Valve moves into neutral
position
A.1.36 Y017 Spool valve fault, valve 3 Magnet output stage
fault within spool valve
Valve moves into neutral
position
ELECTRICAL VALVES
VALVE 3 / VENDI
A.1.37 Y017 Spool valve fault, valve 3 Internal position sensor
fault
Valve moves into neutral
position
ELECTRICAL VALVES
VALVE 3 / VENDI
A.1.38 Y017 Spool valve fault, valve 3 Main piston cannot
return to neutral position
because of oil
contamination.
Undefined and
uncontrolled functions
can occur, DANGER!
Manual actuation must
not have play, slider
must go into the middle
position by itself
ELECTRICAL VALVES
VALVE 3 / VENDI
A.1.39 Y017 Spool valve fault, valve 3 Main piston cannot
return to neutral position
when switched on
because of oil
contamination.
ELECTRICAL VALVES
VALVE 3 / VENDI
A.1.3A Y017 Spool valve fault, valve 3 Main piston deflected
too far
Valve moves into neutral
position
ELECTRICAL VALVES
VALVE 3 / VENDI
A.1.3B Y017 Spool valve fault, valve 3 Floating position is not
reached
Valve moves into neutral
position
ELECTRICAL VALVES
VALVE 3 / VENDI
A.1.3C Y017 Spool valve fault, valve 3 Floating position has
been set manually
No consequences ELECTRICAL VALVES
VALVE 3 / VENDI
A.1.3F Y017 Spool valve fault, valve 3 Setpoint message is
missing or not plausible
Valve moves into neutral
position
ELECTRICAL VALVES
VALVE 3 / VENDI
Configuration message
is missing or not
plausible
Potentiometer or PWM
fault
A.1.40 Y018 Spool valve fault, valve 4 Valve cannot be
recognised by valve bus
No valve operation
available
Signal flow diagram
A002 CAN II pin 4 and 5
A.1.41 Y018 Spool valve fault, valve 4 EEPROM inconsistent Valve moves into neutral
position
Fault
code
Id code Brief description Description Consequences Link FENDIAS / Note