User Manual

all Vario tractors
Tractor / General system
Vario Tractors - Fault Codes
B
Faults
12/1999
0000 000001
B
f
45/58
Capitel Docu-No.
Index
Date Version
Page
Vario Tractors - Fault Codes
9.1.5C Y019 Spool valve fault Floating position has
been set manually
No consequences FRONT POWER LIFT /
VENDI
9.1.5F Y019 Spool valve fault Setpoint message
missing
Valve moves into neutral
position
FRONT POWER LIFT /
VENDI
Configuration message
missing
Setpoint message is not
plausible
Configuration message
is not plausible
Potentiometer or PWM
fault
9.1.A0 A002 ECU, enhanced control EEPROM fault while
storing
Set values (enhanced
controls) are not stored.
9.1.A1 A002 ECU, enhanced control EEPROM fault while
loading
Set values (enhanced
controls) cannot be
read.
9.1.B0 B040 Position sensor Not calibrated No position control
available
FRONT POWER LIFT
calibration code "9002"
9.1.B1 B040 Position sensor Signal fault No position control
available
'Spool valves 2' circuit
diagram
Front power lift
8.5 V supply fault A013 fuse 11
9.1.B2 A004 Depth control setpoint
potentiometer
Not calibrated Setpoint cannot be set FRONT POWER LIFT
calibration code '9001'
9.1.B3 A004 Depth control setpoint
potentiometer
Switch / A004 signal
fault
Setpoint cannot be set Front power lift
9.1.C0 A004 Control console Not available or bus not
connected
9.1.C1 A004 Automatic (switching
from control console to
armrest)
Key fault Front power lift
Fault
code
Id code Brief description Description Consequences Link FENDIAS / Note