User Manual
Table Of Contents
all Vario tractors
Tractor / General system
Vario Tractors - Fault Codes
B
Faults
12/1999
0000 000001
B
f
33/58
Capitel Docu-No.
Index
Date Version
Page
Vario Tractors - Fault Codes
5.1.9A S026 Auxiliary pump flow
monitor
Switch faulty (doesn't
close / is open even
without oil volume)
Plausibility error (wrong
voltage value / Ohm
value)
El. valves 1'circuit
diagram', also refer to
Chapter 9000 Reg. E
Fault code appears 8
seconds after 'Ignition
ON'. Fault code can be
cancelled, but appears
again after 10 minutes.
5.1.9B S025,
S026
LS pump
pressure-operated
switch, auxiliary pump
flow monitor
While engine is running,
interruption between
connector and e-box or
connector and flow
controller
No monitoring El. valves 1'circuit
diagram', also refer to
Chapter 9000 Reg. E
Fault code with engine
running
Already before ignition
ON, interruption
between e-box and
connector (the same
when both components
are disconnected)
No monitoring El. valves 1'circuit
diagram', also refer to
Chapter 9000 Reg. E
Fault code already
present at 'Ignition ON'.
5.1.9E S034 Engine coolant level
switch
Coolant level too low Major engine damage! 'Instrument cluster'
circuit diagram
Fault message can be
cleared only temporarily;
it is repeated every 2
minutes
5.1.9F S034 Engine coolant level
switch
Signal fault No further monitoring 'Instrument cluster'
circuit diagram
5.1.B0 A002 ECU, enhanced control CAN-bus
communication
restricted
EOL reprogramming
necessary
5.1.FF A002 ECU, enhanced control Internal fault
(RAM / EEPROM)
6.1.01 A004 Rear PTO ON / OFF key
in cab
Key / A004 signal fault PTO disengages 'PTO's' circuit diagram REAR PTO
ENHANCED CONTROL
Bus fault A004 / A002
6.1.02 S020 Right external 'Rear
PTO ON / OFF'
pushbutton
Signal fault PTO can be engaged by
pressing emergency key
in cab for 5 seconds.
'PTO's' circuit diagram REAR PTO
ENHANCED CONTROL
Fault
code
Id code Brief description Description Consequences Link FENDIAS / Note