User Manual

all Vario tractors
Tractor / General system
Vario Tractors - Fault Codes
B
Faults
12/1999
0000 000001
B
f
29/58
Capitel Docu-No.
Index
Date Version
Page
Vario Tractors - Fault Codes
4.1.E3 A002 ECU, enhanced control Checksum error
parameter for
accelerator pedal mode
TMS is switched off EOL reprogramming
necessary
4.1.E4 A002 ECU, enhanced control Checksum error
parameter for active
parking function
EOL reprogramming
necessary
4.1.E8 Equipment 'Neumaier
reverse drive facility'
Checksum error on
clutch pedal
potentiometer on
Neumaier reverse drive
facility or clutch
calibration faulty
(Neumaier Service
Manual) calibration code
'4011'
4.1.E9 B016 Values for shift from
range II to I outside
tolerances
Shifting only possible
when stationary
Calibration code '4003'
4.1.EA A002 Internal fault (RAM /
EEPROM)
Continuation in
emergency mode
possible
EOL reprogramming
necessary
4.1.EB B016 Speed range operation No calibration or drifted
values
Continuation in
emergency mode
possible
TRANSMISSION,
OPERATING RANGE;
calibration code '4003'
4.1.EC B029,
B038
or
B055
Specified engine speed
rotary position sensor
('accelerator pedal')
combi-sensor
No calibration or drifted
values
Continuation in
emergency mode
possible
TRANSMISSION,
AUTOMATIC MAXIMUM
OUTPUT CONTROL,
calibration code '4005'
4.1.ED B017 Clutch pedal rotary
position sensor
No calibration or drifted
values
Continuation in
emergency mode
possible
TRANSMISSION,
OPERATING RANGE;
calibration code '4001'
4.1.EE A002 Transmission
characteristic
No calibration or drifted
values
Continuation in
emergency mode
possible
TRANSMISSION,
AUTOMATIC MAXIMUM
OUTPUT CONTROL,
calibration code '4007'
Fault
code
Id code Brief description Description Consequences Link FENDIAS / Note