User Manual

all Vario tractors
Tractor / General system
Vario Tractors - Fault Codes
B
Faults
12/1999
0000 000001
B
f
27/58
Capitel Docu-No.
Index
Date Version
Page
Vario Tractors - Fault Codes
4.1.A0 A009 Transmission control
unit
Actuation fault in
transmission control
module
Continuation in
emergency mode
possible
4.1.A1 A009 Transmission control
unit
Turn angle is not
reached within 2
seconds.
Continuation in
emergency mode
possible
Mechanical test: Check
smooth adjustment
action in emergency
operation
TRANSMISSION,
TRANSMISSION
ADJUSTMENT refer to
Service Information
26/04
4.1.A2 A009
A001
or
A002
Transmission control
unit
CAN-bus actuation fault Continuation in
emergency mode
possible
Chapter 9000 Reg. E -
Testing CAN - BUS
TRANSMISSION,
TRANSMISSION
CONTROL
4.1.A3 A009 Transmission control
unit
Fault or logical error in
incremental sensor
signal (actual position
signal)
Continuation in
emergency mode
possible
TRANSMISSION,
TRANSMISSION
CONTROL
4.1.A4 A009 Transmission control
unit
Fault or logical error in
ECU signal.
Continuation in
emergency mode
possible
TRANSMISSION,
TRANSMISSION
CONTROL
4.1.A5 A009 Transmission control
unit
Initial reference (=zero
position) could not be
reached during ignition
'ON'
Continuation in
emergency mode
possible
TRANSMISSION,
TRANSMISSION
ADJUSTMENT refer to
Service Information
26/04
4.1.A6 A009 Transmission control
unit
Reference point signal
fault during operation
Continuation in
emergency mode
possible
TRANSMISSION,
TRANSMISSION
CONTROL
4.1.B0 all Bus users Initialisation error Restricted CAN-bus
data communication
Chapter 9000 Reg. E -
Testing CAN BUS
4.1.B1 Y001
Y002
Speed range control Illogical speed range
operation (=fatal error)
Continuation in
emergency mode
possible
Fault
code
Id code Brief description Description Consequences Link FENDIAS / Note