User Manual
Table Of Contents
all Vario tractors
Tractor / General system
Vario Tractors - Fault Codes
B
Faults
12/1999
0000 000001
B
f
22/58
Capitel Docu-No.Index
Date Version
Page
Vario Tractors - Fault Codes
4.1.36 'Rear PTO automatic'
key on membrane
keypad
Signal fault Function not available see Service Training ML
200 (X
990.005.023.027en)
4.1.37 'Front PTO automatic'
key on membrane
keypad
Signal fault Function not available Service Training ML 200
(X 990.005.023.027en)
4.1.38 'Store forward
transmission ratio' key
on membrane keypad
Signal fault Function not available Service Training ML 200
(X 990.005.023.027en)
4.1.41 B011 Engine speed Hall
sensor 2
Signal fault Continuation in
emergency mode
possible
'Transmission control'
circuit diagram
TRANSMISSION,
CRUISE CONTROL
12 V supply fault A013 fuse 2
4.1.42 B014 Hall sensor for
accumulator shaft speed
(partially also defined by
'Hydrostat')
Signal fault Continuation in
emergency mode
possible
'Transmission control'
circuit diagram
TRANSMISSION,
CRUISE CONTROL
8.5 V supply fault A013 fuse 16
4.1.44 B010 Engine speed Hall
sensor 1
Signal fault Continuation in
emergency mode
possible
'Transmission control'
circuit diagram
TRANSMISSION,
CRUISE CONTROL
12 V supply fault A013 fuse 4
4.1.45 B015 Bevel pinion speed
(=travel speed) Hall
sensor
Signal fault Continuation in
emergency mode
possible
'Transmission control'
circuit diagram
TRANSMISSION,
CRUISE CONTROL
8.5 V supply fault A013 fuse 7
4.1.50 S017 'Transmission oil filter
clogged' switch
Filter clogged No further indication of
clogging
'Transmission control'
circuit diagram
TRANSMISSION,
TRANSMISSION
OIL/FILTER switch
function not active
under 50° oil
temperature
Fault
code
Id code Brief description Description Consequences Link FENDIAS / Note