User Manual
Table Of Contents
FENDT 900 Vario COM III Faults
B
OVERALL SYSTEM/TRACTOR
Fault Code Table FENDT 900 Vario – COM III
919 .. 1001- 934 .. 1001-
922 .. 1001-
925 .. 1001-
928 .. 1001-
931 .. 1001-
0000 B T000002
Version 3
21/09/2007
48
Crop_this_page
0F.1.19 A038 - ECU, central electrical sys-
tem
Sensor supply voltage too
high or too low
0F.1.1A A038 - ECU, central electrical sys-
tem
Main supply voltage too high
or too low
0F.1.1B A038 - ECU, central electrical sys-
tem
Processor supply voltage too
high or too low
0F.1.1D M002 - Front wiper motor Function non-operable Circuit diagram
Sheet 16
0F.1.1E M004 - Rear wiper motor Function non-operable Circuit diagram
Sheet 16
0F.1.1F M010 - Fuel pump Function non-operable Circuit diagram
Sheet 17
0F.1.20 A050 - ECU, basic control unit
A007 - Instrument panel
Communication problem: no
information from instrument
panel
0F.1.21 A050 - ECU, basic control unit Checksum error over address
range: 0-128d
0F.1.22 A050 - ECU, basic control unit Checksum error over address
range for diagnostic parame-
ters
0F.1.23 A050 - ECU, basic control unit Communication problem: no
information from transmission
(engine speed, theo. speed,
reverse operation)
0F.1.24 A050 - ECU, basic control unit Communication problem: no
information from enhanced
controls (brake)
0F.1.25 A050 - ECU, basic control unit
A039 - MFA, multifunction armrest
Communication problem: no
information from MFA (Hydr3
button, Hydr4 button)
Fault
code
DIN brief description Cause Consequences Reference FENDIAS/Note