0A.1.F6 Y060 - Hydraulic oil pre-heater sole-
noid valve (rear)
Actuation fault No further valve heat-
ing possible
Circuit diagram
Sheet 7
0A.1.F7 Y061 - Hydraulic oil pre-heater sole-
noid valve (front)
Actuation fault No further valve heat-
ing possible
Circuit diagram
Sheet 7
0A.1.F8 Y084 - Control pressure increase so-
lenoid valve in Power Beyond mode
Actuation fault No control pressure
increase possible
Circuit diagram
Sheet 7
0A.1.FA S067 - Switch (external), valve actua-
tion, raise
Faulty button, signal fault Button inoperable un-
til next trouble-free
cold start
Circuit diagram
Sheet 7
0A.1.FB S068 - Switch (external), valve actua-
tion, lower
Faulty button, signal fault Button inoperable un-
til next trouble-free
cold start
Circuit diagram
Sheet 7
0A.1.FC S067 - Switch (external), valve actua-
tion, raise
S068 - Switch (external), valve actua-
tion, lower
Double actuation, faulty but-
ton, signal fault
Circuit diagram
Sheet 7
0A.1.FD Y082 - Lower link stabiliser I sole-
noid valve
Fault with locking No locking possible Circuit diagram
Sheet 9
0A.1.FE Y083 - Lower link stabiliser II sole-
noid valve
Fault with opening No opening possible Circuit diagram
Sheet 9
X stands for the valve number, e.g. 0A.1.10 = position 1 valve does not report to CAN or 0A.1.37 = position pickup sensor error in
position 3 valve
0A.1.X0 Y071 - Control valve
Y072 - Control valve
Y074 - Control valve
Y075 - Control valve
Y076 - Control valve
Y078 - Control valve
Y079 - Control valve
Y080 - Control valve
Valve does not report to CAN
bus (X= valve number)
Valve moves to neu-
tral and locks
Circuit diagram
Sheet 8
Fault
code