User Manual
Table Of Contents
FENDT 900 Vario COM III Faults
B
OVERALL SYSTEM/TRACTOR
Fault Code Table FENDT 900 Vario – COM III
Service Training
919 .. 1001- 934 .. 1001-
922 .. 1001-
925 .. 1001-
928 .. 1001-
931 .. 1001-
0000 B T000002
Version 3
21/09/2007
35
Crop_this_page
09.1.EF Y070 - EHR cut-off valve, front No configuration message. Valve moves to neu-
tral and locks
Pilot pressure OFF
09.1.EF Y070 - EHR cut-off valve, front Setpoint message not plausi-
ble
Valve moves to neu-
tral and locks
Pilot pressure OFF
09.1.EF Y070 - EHR cut-off valve, front Implausible config. message Valve moves to neu-
tral and locks
Pilot pressure OFF
0A.1.A0 Auxiliary control units EEPROM fault while saving Valve moves to neu-
tral and locks
0A.1.A1 Auxiliary control units EEPROM fault while loading Valve moves to neu-
tral and locks
0A.1.A2 Auxiliary control units More valves connected than
registered via EOL program-
ming
0A.1.B5 A039 - MFA, multifunction armrest Joystick centre position detec-
tion faulty (electrical fault)
Valve position not
functioning,
lock valve
0A.1.B6 A039 - MFA, multifunction armrest Linear module 1 (rocker) not
calibrated
Valve position not
functioning
0A.1.B7 A039 - MFA, multifunction armrest Faulty linear module 1 (rocker) Valve position not
functioning,
lock valve
0A.1.B8 A039 - MFA, multifunction armrest Linear module 2 (rocker) not
calibrated
Valve position not
functioning
0A.1.B9 A039 - MFA, multifunction armrest Faulty linear module 2 (rocker) Valve position not
functioning,
lock valve
Fault
code
DIN brief description Cause Consequences Reference FENDIAS/Note