B
OVERALL SYSTEM/TRACTOR
Fault Code Table FENDT 900 Vario – COM III
919 .. 1001- 934 .. 1001-
922 .. 1001-
925 .. 1001-
928 .. 1001-
931 .. 1001-
0000 B T000002
Version 3
21/09/2007
28
Crop_this_page
08.1.45 A039 - MFA, multifunction armrest
Transport button, SAH rear power lift
Faulty button, signal fault Button inoperable un-
til next trouble-free
cold start
08.1.46 A039 - MFA, multifunction armrest
Control button, SAH rear power lift
Faulty button, signal fault Button inoperable un-
til next trouble-free
cold start
08.1.47 A039 - MFA, multifunction armrest
Quick entry button, SAH rear power
lift
Faulty button, signal fault Button inoperable un-
til next trouble-free
cold start
08.1.48 A039 - MFA, multifunction armrest
Button, rear power lift
Communication fault (previ-
ously 99)
Button inoperable un-
til next trouble-free
cold start
08.1.49 Y055 - Rear pressure compensator
lock valve
Faulty valve Valve moves to neu-
tral and locks
Circuit diagram
Sheet 7
08.1.4A Y062 - Solenoid valve, field pressure
control (REAR)
Faulty valve Valve moves to neu-
tral and locks
Circuit diagram
Sheet 7
08.1.4B A039 - MFA, multifunction armrest
Button, auto rear power lift
Faulty button (output via
Teach-in)
No auto mode
08.1.A0 Y077 - EHR cut-off valve, rear A050 ECU, basic control unit
EEPROM error when saving
08.1.A1 Y077 - EHR cut-off valve, rear A050 ECU, basic control unit
EEPROM error when reading
08.1.A2 Y077 - EHR cut-off valve, rear EEPROM error (valve) Valve moves to neu-
tral and locks
08.1.A3 Y077 - EHR cut-off valve, rear RAM_Test Valve moves to neu-
tral and locks
Pilot pressure OFF
08.1.A4 Y077 - EHR cut-off valve, rear Flash_Test Valve moves to neu-
tral and locks
Pilot pressure OFF
Fault
code
DIN brief description Cause Consequences Reference FENDIAS/Note