User Manual

Fendt 300 Vario
Tractor / General system
Vario Tractors - Fault Codes
B
Faults
12.06.2006
0000 000022
B
b
17/21
Capitel Docu-No.
Index
Date Version
Page
Vario Tractors - Fault Codes
1E.1.24
Y006 Engine brake flap valve Valve faulty Circuit diagram 'Deutz
engine control'
SERDIA (clear fault)
FC:004A
1E.1.25
Y006 Engine brake flap valve Cable break or short
circuit
Circuit diagram 'Deutz
engine control'
SERDIA (clear fault)
FC:0052
1E.1.26
Y024 Air-conditioning
compressor magnetic
clutch
Cable break or short
circuit
Circuit diagram 'Deutz
engine control'
SERDIA (clear fault)
FC:0053
1E.1.27
G001 Battery Short circuit to battery or
short to ground
Starting not possible SERDIA (clear fault)
FC:00B6, 00B7, 00BA,
00BC
1E.1.2C
K065 Start relay Cable break or short
circuit
Starting not possible SERDIA (clear fault)
FC:00DF, 00E0
1E.1.30
B004 Air filter Pressure loss above
target range
Clean/change air filter Circuit diagram'EDC
control'
SERDIA (clear fault)
FC:000B, 00F2
1E.1.34
S034 Switch, coolant level Coolant outside of
specified range
Check coolant level Circuit diagram'EDC
control'
SERDIA (clear fault)
FC:0025
1E.1.37
A051 ECU, engine control unit
(EDC7)
Fan speed outside of
specified range
Clean/change air filter Circuit diagram'EDC
control'
SERDIA (clear fault)
1E.1.3A
A051 ECU, engine control unit
(EDC7)
Misfire SERDIA (clear fault)
FC:002F
1E.1.50
A091 Metering unit Metering unit valve not
connected, short circuit to
battery or short to ground
Error message appears
stating that the engine will
stop in approx. 5 minutes
Circuit diagram'EDC
control'
SERDIA (clear fault)
FC:00B0, 00B1, 00B2,
00B3
1E.1.51
B086 Rail pressure sensor, rail
pressure limiting valve
Rail pressure limiting
valve opening failure.
an error message is
displayed stating that the
engine will stop in approx.
5 minutes
SERDIA (clear fault)
FC:00D0, 00EC
1E.1.52
B086 Rail pressure sensor Cable break or short
circuit
an error message is
displayed stating that the
engine will stop in approx.
5 minutes
Circuit diagram 'Deutz
engine control'
SERDIA (clear fault)
FC:00D1, 00D2
1E.1.53
B086 Rail pressure sensor Rail pressure outside
target range
Error message appears
stating that the engine will
stop in 4 minutes
Circuit diagram 'Deutz
engine control'
SERDIA (clear fault)
FC:00D3, 00D4, 00D5,
00D6, 00D7, 00D8
Fault
code
Id code Brief description Description Consequences Link FENDIAS / Note