User Manual

FENDT 400 Vario COM III, FENDT 700 Vario COM III, FENDT 800 Vario COM III Faults
B
OVERALL SYSTEM/TRACTOR
Fault code table COM III
400 .. 1001- 724 .. 1001- 731 .. 1001-
401 .. 1001- 725 .. 1001-
402 .. 1001- 726 .. 1001-
403 .. 1001- 727 .. 1001-
404 .. 1001- 729 .. 1001-
0000 B T000434
Version 1
20/09/2007
48
Crop_this_page
A.1.B0 A034 - Driving switch, CAN bus
Crossgate lever
Not calibrated Valves cannot be op-
erated
Calibration code "1001"
A.1.B1 A034 - Driving switch, CAN bus
Crossgate lever
X axis signal fault Valves cannot be op-
erated
Wiring diagram
Sheet 26
ELECTRICAL
VALVES OPERATION
A.1.B2 A034 - Driving switch, CAN bus
Crossgate lever
Y axis signal fault Valves cannot be op-
erated
Wiring diagram
Sheet 26
ELECTRICAL
VALVES OPERATION
A.1.B3 A034 - Driving switch, CAN bus
Crossgate lever
X and Y axis signal fault;
crossgate lever missing
Valves cannot be op-
erated
Wiring diagram
Sheet 26
ELECTRICAL
VALVES OPERATION
A.1.B4 A034 - Driving switch, CAN bus
Crossgate lever
Zero position signals of X and
Y axes are not identical to the
"centre position" signal (=plau-
sibility check)
Valves cannot be op-
erated
Wiring diagram
Sheet 26
ELECTRICAL
VALVES OPERATION
A.1.B5 A034 - Driving switch, CAN bus
Crossgate lever
"Centre position" signal fault Valves cannot be op-
erated
Wiring diagram
Sheet 26
ELECTRICAL
VALVES OPERATION
A.1.C0 A004 - ECU, control panel Not available or bus not con-
nected
A.1.C1 A004 - ECU, control panel Automatic system (switching
from control panel/joystick)
button faulty
ELECTRICAL
VALVES OPERATION
A.1.C2 A004 - ECU, control panel Valve locking button faulty ELECTRICAL
VALVES OPERATION
A.1.C3 A004 - ECU, control panel Floating position button faulty No floating position ELECTRICAL
VALVES OPERATION
A.1.C4 A004 - ECU, control panel Time function button faulty No time function ELECTRICAL
VALVES OPERATION
A.1.C5 A004 - ECU, control panel Switching function button
faulty
ELECTRICAL
VALVES OPERATION
Fault
code
DIN brief description Cause Consequences Reference FENDIAS / Note