Owner manual

Guilin Feiyu Electronic Technology Co., Ltd
Guilin Feiyu Electronic Technology Co., Ltd http://www.feiyudz.cn service@feiyu-tech.com
Page 21
“Fail-Safe” setting
In RC mode, need the RC and RC receiver both must have ―Fail-Safe‖ function. First of all, SW2
switch setting into can use " Return To Launch (RTL) " mode. Then, through RC set RC receiver
―Fail-Safe‖ protection, when RC out of control, the SW2 signal will switch to " Return To Launch
(RTL)" position. Pay attention to set the throttle control stick to the cruise throttle position, or you will
have the danger of stall.
In DRRC mode, because the use of Remote Adaptor, will automatically detect radio
communication is normal or not, if the communication interrupt, after about 5 seconds will automatic
into " Return To Launch (RTL) " mode.
At "RC remote control Mode" increased max distance flight setting. At "RC remote control
mode‖, if the plane distance from home point more than the ―Max Distance Setting ‖which you set, the
Panda2 will automatically into Auto Return To Launch Mode(RTH), in order to prevent aircraft fly lost
situation due to no ―Fail-Safe‖ setting of the Remote Controller. Panda2 default flight max distance is
4000 meters. Also at "RC remote control mode‖, increased the judgment of RC receiver and Panda2
connectivity, if they all disconnect , the Panda2 will automatic into Auto Return To Launch
Mode(RTH).
Setting software: FY-DOS&41AP-SETTING V1.1 (2012.12.5)
http://www.feiyu-tech.com/download-en.php?id=61
“Max Distance Setting ” settings window :