FAIL-SAFE setting
The RC receiver remote control mode uncontrolled return of function, you need to
use with runaway protection function remote and the receiver.
Failsafe remote control receiver when no signal is received, output a default set
of rudder. Various models of remote control set runaway protection have said, the
reference to the remote control manual.
Return channel CH6 need to set connected to SW2 is out of control out of control
protection switch to the status of the return. Aileron, elevator, rudder channel is set to
loose rod status, throttle setting to cruise throttle position.
If debugging balanced mode, the following Futaba remote control T10CHG example
set runaway protection. Settings, turn off the power to the aircraft, to avoid setting the
motor starts.
First enter the remote control setup menu to find the set of "F / S"; into the F / S menu,
the lever into the neutral position, rudder trimming to maintain the status adjusted, the
throttle lever to the cruise throttle position, the CH6 cut to return mode . Then in all open
channel F / S, and often set by the "PUSH" button, set successfully as shown.
After setting the aircraft is powered off control check has successfully entered the return
mode. Pay attention to safety, to prevent the Failsafe motor rotation, met items
cause damage.
Fixed altitude & Heading lock Mode instruction
Fixed altitude & Heading lock Mode – This mode maintains aircraft flight course & holds
the altitude on activation. By using GPS data, the system automatically corrects flight
course deviation & maintains straight-line flight.
Attention: Please make sure the RC stick is released when you switch into Fixed
altitude & Heading lock Mode. The FY-41AP can record current RC stick position and