10
4. Right-click on HID-compliant device and select Properties. You will see the device type I Human Interface
Device, which indicates that the Rockey501 reader has been connected successfully (both the red and green
indicators are on).
Figure 2 Human Interface Device
3.3 Hardware Prompt Message
The red indicator, the green indicator, and the buzzer can give you some messages on the operating status of the
reader.
These messages include:
1) Both the red indicator and the green indicator are brought on if the power is available when connecting
the ROCKEY501 reader to the computer;
2) During the self-test after the ROCKEY501 reader is powered up and enumerated, the buzzer beeps for a
long time if the checksum of firmware is incorrect; the buzzer beeps for a short time twice if the antenna board is
not initialized successfully, while the red indicator is on and the green winks;
3) If the self-test is successful and the RF is connected properly, the device has been started normally and is
available for operations;
4) When a USB communication instruction is received, the green indicator is on and the red winks; after the