Installation Guide
 (E) 4/07
ASSEMBLY INSTRUCTIONS FOR OL5413
Bulb
(not included)
Glass Plate
IMPORTANT
TURN OFF THE POWER AT THE MAIN FUSE 
OR CIRCUIT BREAKER BOX
BEFORE STARTING INSTALLATION
Lock Washer
Rubber Washer
Coupler
Finial
  Carefully unpack and identify all parts before 
assembly. Bulb is not included.
1.  If you are replacing an existing fixture, disconnect
and remove the old fixture. Expose the supply
wiring from the outlet box.
2.  Screw the small threaded pipe 3 complete turnsinto 
the flat side of mounting strap and lock inplace 
with hex nut.
3.  Fasten the mounting strap to the outlet box using
the two screws supplied with the outlet box.
4.  Spread the electrical wires so that the black wires
are on one side of the outlet box and the whitewires 
are on the other side.
5.  Grounding Connection:
   This fixture is provided with a ground wire.
Connectfixture ground wire to ground wire from 
outletbox with wire connector (not provided).
 
   Never connect ground wire to black or white supply 
wires.
6.  To make electrical connections:
  Connect the white wire(s) from the fixture to the
white wire of the outlet box. Connect the black
wire(s) from the fixture to the black wire of the
outlet box. NOTE: Black outlet box wire may be
red, round & smooth and/or have copper conductor.
White outlet box wire may be square & ridgedand/ 
or have a silver conductor.
7.  Place fixture through short threaded pipe so that 
fixture sits flushagainst ceiling. Be sure all wires 
are inside fixture. Secure fixture to ceiling by 
screwing coupler onto small threadedpipe. Coupler 
must turn at least 3 times, if it does not youmust 
lengthen threaded pipe accordingly.
8.  Install bulbs (not included). See relamping label 
located atsocket area for type and maximum 
allowed wattage.
9.  Install a hex nut onto one end ofthreaded pipe 
leaving about 1/2"(13mm) thread exposed. Screw
same end of threaded pipe intocoupler. Tighten hex 
nut.
10.Carefully slip glass platethrough same pipe until it 
tucks into bottom of fixture.Then slip rubber 
washer and secure all together byfastening with 
finial. IMPORTANT: Do not over tightenfinial.
Supply 
Ground Wire
Mounting Strap
Short Threaded Pipe
Long Threaded Pipe
Outlet Box 
Mounting Screws
(not supplied)
Fixture 
Ground Wire
Fixture 
Wire
Fixture
Supply Wire
Outlet Box Ceiling