4.3 Interfaces
4.3.1 Ethernet Interface on connector X2 (10/100Tbase)
The Reader has an integrated 10 / 100 base-T network port for an RJ-45. Connection is made on X2 and has
an automatic “Crossover Detection” according to the 100BASE-T Standard.
With structured cabling CAT 5 cables should be used. This ensures a reliable operation at 10 Mbps or 100
Mbps.
The prerequisite for using TCP/IP protocol is that each device has a unique address on the network. All
Readers have a factory set IP address.
Table 8: Standard factory configuration of the Ethernet connection
Network Address
IP-Adress 192.168.10.10
Subnet-Mask 255.255.0.0
Port 10001
DHCP OFF
NOTE:
The reader is equipped with a DHCP ready Ethernet Interface.
4.3.2 USB Interface on connector X3 (Host Kommunikation)
The USB socket on the board is terminal X3. The pinout is standardized. The data rate is reduced to 12 Mbit
(USB full speed). A standard USB-cable can be used.
Fig. 6: USB-Interface for host communication
NOTE:
The length of the USB-cable can have a max. of 5m (20 inch). It is not allowed to use longer cables.