IDENTIFICATION Installation ID ISC.LRU3000 / ID ISC.
IDENTIFICATION ID ISC.LRU3000 / LRU3500 Note Note Note © Copyright by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg (Germany) Tel.: +49 6471 3109-0 http://www.feig.de identification-support@feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document and giving it to others and the use or communication of the contents thereof are forbidden without express authority.
IDENTIFICATION ID ISC.LRU3000 / LRU3500 Contents Contents Contents 1 Safety Instructions / Warning - Read before start-up ! 5 2 Performance Features of Reader Family ID ISC.LRU3000 6 2.1 Performance features ........................................................................................................ 6 2.2 Available Reader types ..................................................................................................... 6 2.3 Available Accessories .........................
IDENTIFICATION ID ISC.LRU3000 / LRU3500 Contents 6 Technical Data 25 7 Radio Approval 27 7.1 Europe (CE)...................................................................................................................... 27 7.2 USA (FCC) and Canada (IC) ............................................................................................ 28 7.2.1 USA (FCC) and Canada (IC) warning notices ...................................................... 28 7.2.2 Label Information ...............
IDENTIFICATION ID ISC.LRU3000 / LRU3500 1 Safety Instructions 1 Safety Instructions ► ► ► ► ► ► ► ► ► ► ► The device may only be used for the intended purpose designed by for the manufacturer. The operation manual should be conveniently kept available at all times for each user. Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries.
ID ISC.LRU3000 / LRU3500 IDENTIFICATION 2 Performance Features of Reader Family ID ISC.LRU3000 2 Performance Features of Reader Family ID ISC.LRU3000 2.1 Performance features The Reader has been developed for reading passive data carriers, so-called „Smart Labels“, using an operating frequency in the UHF range. 2.2 Available Reader Types The following Readers are available: Table 1: Available Reader Types Reader type Description ID ISC.LRU3500-EU Device version for Europe with PoE ID ISC.
IDENTIFICATION ID ISC.LRU3000 / LRU3500 3 Installation 3 Installation The Reader is designed for wall-mount, including outdoors. Holes for mounting on a wall are provided in the housing. For outdoor installation, the protective cap must be used according to the list in chapter Annex AAccessories. It is not necessary to open the reader housing mounting. Fig.
IDENTIFICATION ID ISC.LRU3000 / LRU3500 4 Terminals 4 Terminals On the lower side of the reader housing the different cable connectors are positioned. Figure 2 shows the arrangement of the connectors and table 3 shows which connection for the different cables are used for. Table 4 shows the available push buttons.
IDENTIFICATION 4.1 ID ISC.LRU3000 / LRU3500 4 Terminals Antenna Connection The external SMA antenna connectors are positioned on the lower side of the reader. The maximum tightening torque for the SMA sockets is 0.45 Nm (4.0 lbf in). CAUTION: • Exceeding the tightening torque will destroy the plug. Table 5: External antenna connection Terminal Description ANT 1 - 4 Connection for external antennas (input impedance 50Ω) Fig.
IDENTIFICATION 4.2 ID ISC.LRU3000 / LRU3500 4 Terminals Power Supply 4.2.1 Power Supply via connection X1 The supply voltage of 24 V DC has to be connected to Terminal X1 Table 6: Pin assignment for power supply Terminal Abbreviation Description X1 / Pin 1 VDC Vcc – supply voltage 24VDC +-5% X1 / Pin 2 GND Ground – supply voltage Fig.
IDENTIFICATION ID ISC.LRU3000 / LRU3500 4 Terminals 4.2.2 Power Supply via Power over Ethernet (PoE) Optional the reader (only LRU3500) can be powered via the LAN connector on X2 with the use of a PoE „Power over Ethernet“ power supply according to IEEE802.3at*, Class4 (30/25,5Watt). The DC supply can be achieved via the free pin’s 4,5 and 7,8 (Midspan-Power). Also a “Phantom Powering” (Inline-Power) via the signal pin’s 1,2,3, and 6 is possible.
IDENTIFICATION 4.3 ID ISC.LRU3000 / LRU3500 4 Terminals Interfaces 4.3.1 Ethernet Interface on connector X2 (10/100Tbase) The Reader has an integrated 10 / 100 base-T network port for an RJ-45. Connection is made on X2 and has an automatic “Crossover Detection” according to the 100BASE-T Standard. With structured cabling CAT 5 cables should be used. This ensures a reliable operation at 10 Mbps or 100 Mbps.
IDENTIFICATION ID ISC.LRU3000 / LRU3500 4 Terminals 4.3.3 USB Host Interface on connector X4 The USB-Port X4 can be used for a standard USB Flash drive. Fig. 7: USB-Host Interface NOTE: USB Host shall not be used when the reader is powered via Power over Ethernet (PoE) 4.3.4 RS232 Interface on connector X6 The RS232 interface is connected on X6. The transmission parameters can be configured by means of software protocol. Fig. 8: RS232 interface pin-outs on X6 Fig.
IDENTIFICATION ID ISC.LRU3000 / LRU3500 4 Terminals 4.3.5 RS485 Interface on connector X6 The connection of the RS485 interface take place via the X6 connector as well. The interface parameter can be configured via software protocols.. Fig.
IDENTIFICATION ID ISC.LRU3000 / LRU3500 4 Terminals 4.3.5.1 Address assignment of RS485 for bus operation For bus operation the Reader can be assigned the required bus address via software. The address is assigned by the host computer. The software is used to assign addresses “0” through “254” to the Reader. A potential termination of the interface bus can be configured by the software as well.
IDENTIFICATION • • ID ISC.LRU3000 / LRU3500 4 Terminals The digital outputs OUT1 and OUT2 are not available, if the data-clock interface is activated. The data as well as the clock need to be supplied with an external voltage. The output is configured for max. 24 V DC / 30 mA. See Notes below for resistor values Fig. 12: Wiring Example NOTE: • • • Please consider possible limitations of the Wiegand Controller regarding the used supply voltage.
IDENTIFICATION 4.4 ID ISC.LRU3000 / LRU3500 4 Terminals Digital Inputs on connector X5 The optocouplers on Terminal X5 are galvanically isolated from the Reader electronics and must therefore be externally supplied. Fig. 13: Optocoupler pin-outs IN1 – IN5 Fig. 14: Internal and possible external wiring of the optocoupler inputs Optocoupler input (X5 / IN1-5): The input LED associated with the optocoupler is connected internally to a series resistor of 500 Ω.
IDENTIFICATION ID ISC.LRU3000 / LRU3500 4 Terminals Table 10: Shows the necessary external resistors for various external voltages Uext External voltage Uext Required external series resistor Rext 5 V ... 10 V --- 11 V ... 15 V 270 Ω 16 V ... 20 V 560 Ω 21 V ... 24 V 820 Ω NOTE: • • The input is configured for a maximum input voltage of 5-10 V DC and an input current of max. 20 mA. Polarity reversal or overload on the input will destroy it.
IDENTIFICATION 4.5 ID ISC.LRU3000 / LRU3500 4 Terminals Outputs on connector X5 4.5.1 Digital outputs on connector X5 Optocoupler output (X5/1-2): The transistor connections, collector and emitter, of the optocoupler output are galvanically isolated from the Reader electronics and are carried to the outside without any internal ancillary circuitry on Terminal X5. The output must therefore be powered by an external power supply. Fig. 15: Optocoupler -Outputs OUT1-2 Fig.
IDENTIFICATION ID ISC.LRU3000 / LRU3500 4 Terminals 4.5.2 Relay outputs on connector X5 There are 3 relay outputs available on connector X5. Fig. 17: Relay output pin-outs REL1-3 CAUTION: • The relay output is configured for max. 24 V DC / 2 A constant load. • The switching current must not exceed 1A. • The relay output is intended for switching resistive loads only. If an inductive load is connected, the relay contacts must be protected by means of an external protection circuit. Fig.
ID ISC.LRU3000 / LRU3500 IDENTIFICATION 5 Operating and Display Elements 5 Operating and Display Elements 5.1 Status LEDs Table 11 Shows the possible status of the LEDs: Host Communication Warning ANT 1- 4 Input Output RUN Green Yellow Red ON OFF ON Boot sequence (ca.
ID ISC.LRU3000 / LRU3500 IDENTIFICATION Green Yellow Red 5 Operating and Display Elements Description Configurations-Reset: FLASH FLASH FLASH (light in sequence) ON ON ON While T1 is pushed and hold for at least 5s After T1 has been pushed and hold for 5s. Configuration Reset has been finished. Input / Output LED (yellow): Configurable LED. Can display the status of a digital input or output ANT 1 – 4: Green 5.
ID ISC.LRU3000 / LRU3500 IDENTIFICATION 5.3 5 Operating and Display Elements Reader Power adjustment To achieve the optimum reading performance it is necessary to set the reader output power to the highest allowed value. This depends on the used reader type (EU / FCC) and the regulation in the country were the reader is used. 5.3.1 EU-Reader according to EN302 208 According to the standard EN302 208 the maximum radiated power is 2 W e.r.p. (Effective Radiated Power) in countries of the European Union.
ID ISC.LRU3000 / LRU3500 IDENTIFICATION 5 Operating and Display Elements If a linear polarized antenna is used which gain is less then 6 dBi (factor 4), or if a circular polarized antenna is used which gain is less then 9dBic the reader can always be configured to an output power of 1W. Antenna Gain < 6dBi → Pout = 1 W This would be the case if the FEIG standard antennas ANT.U170/170 -FCC (4dBic) or ANT.U270/270 -FCC (8,7dBic) are used.
IDENTIFICATION ID ISC.LRU3000 / LRU3500 6 Technical Data 6 Technical Data MECHANICAL DATA Housing Aluminum powder-coated Dimension (W x H x D) 259,8 mm x 157,3 mm x 68 mm 10.23 inch x 6.19 inch x 2.68 inch Weight 2,0 kg (4.4 lb) Protection Class IP 53 (with protection cap IP64) Colour RAL 9003 (Signal White) ELECTRICAL DATA Power Supply • ID ISC.LRU3000 • ID ISC.LRU3500 24 V DC ± 5 % (Noise Ripple: max. 150 mV) 24 V DC ± 5 % (Noise Ripple: max. 150 mV) or Power over Ethernet (min.
IDENTIFICATION ID ISC.LRU3000 / LRU3500 6 Technical Data Outputs • 2 x Optocoupler • 3 x Relay (1 x normal open) 24 V DC 24 V DC load) / 30 mA (galvanically isolated) / 1 A (switching current), (2A constant Inputs 5 x Optocoupler max.
IDENTIFICATION ID ISC.LRU3000 / LRU3500 7 Radio Approval Vibration EN 60068-2-6 10 Hz to 150 Hz: 0,075 mm / 1 g Shock EN 60068-2-27 Acceleration 30 g APPLICABLE STANDARDS Radio Regulation • Europe • USA • Canada EN 302 208 FCC 47 CFR Part 15 IC RSS-Gen, RSS-247 EMC EN 301 489 Safety Low Voltage Human Exposure EN 62368-1 EN 50364 7 Radio Approval 7.1 Europe (CE) Hereby, FEIG ELECTRONIC GmbH declares that the radio equipment type ID ISC.LRU3000/3500 is in compliance with Directive 2014/53/EU.
IDENTIFICATION 7.2 ID ISC.LRU3000 / LRU3500 7 Radio Approval USA (FCC) and Canada (IC) 7.2.1 USA (FCC) and Canada (IC) warning notices Product name: ID ISC.LRU3000-FCC ID ISC.LRU3500-FCC Reader name: ID ISC.LRU3000-FCC ID ISC.LRU3500-FCC FCC ID: IC: Notice for USA and Canada PJMLRU3000A 6633A-LRU3000A This device complies with Part 15 of the FCC Rules and with RSS-247 of Industry Canada. Operation is subject to the following two conditions.
IDENTIFICATION ID ISC.LRU3000 / LRU3500 7 Radio Approval 7.2.2 Label Information The following information must be placed at the outer side of the housing in which the reader is mounted. Contains FCC ID PJMLRU3000A Contains IC: 6633A-LRU3000A 7.2.3 Installation with FCC / IC Approval FCC-/IC-NOTICE: To comply with FCC Part 15 Rules in the United States / with IC Radio Standards in Canada, the system must be professionally installed to ensure compliance with the Part 15 certification / IC certification.
IDENTIFICATION Annex A: ID ISC.LRU3000 / LRU3500 7 Radio Approval Accessories Following optional accessories are available: Order No. Article Description Plastic Sealing Cap for Reader Connectors with Steel Conduit Pipe Thread (PG) for ID ISC.LRU3x00 and ID ISC.LRU1002 3558.000.00 ID ISC.LR.CSC-IP64 Connector Sealing Cap 3831.000.00 ID ISC.LRU3x00-MS Mounting Rail Set Mounting Rail Set for ID ISC.LRU3x00 and ID ISC.LRU1002 ID ISC.ANT.