FEIGELECTRONICGmbHLangeStr.4D35781Weilburg,GermanyTel.:+49(0)6471/31090Fax:+49(0)6471/310999www.feig.deEmail:info@feig.de
PD_FSAS250_Eng_120102.Doc
4. MountingofthestationaryAntenna:
Antenna
Mobile unit
Side view Front view
Antenna
Mobile unit
Figure:MountingofAntennaondoor
5. StationaryAntenna+aluminummountingbracket:
45
1
0
5
7
,
6
1
5
24,5
39
4
4
2
Figure:StationaryAntenna+aluminummountingbracket
6. TechnicalData:
Connectiondata: Supplyvoltage+24V+/10%,typical50mA.
SerialbidirectionalInterfaceRS485/19,2kBaud
Digitaloutputs: Threeconfigurableoutputswiththefollowingstandardsetting:
- Output1and2:Safetyoutput(N.O.)with8.2kΩterminalresistorand
testingofterminalresistor.
- Output3:Breakawayoutput
(N.C.
contactat24Vwith560Ωlimitingresistor)
ConnectingtoAencodedM12plugwith35cmlongcable.
Themax.allowedLengthofthecustomermountedcableis50m
Radio: Operatingrange2400to2483.5MHz
40channels,Ratedoutputpower0dBm
Temperaturerange: Operatingrange–40to+70°C,
Storage
range–40to+70°C(recommended+20°C)
Protectionclass: IP65
Max.tolerablespeed:6000U/min
Resolution:13Bit/turn(8192Increments/turn)
Counterofturns:15Bit
Weight: Withoutcablebutwithmagnetholder220g
Lifetimeofbattery:typical10years
Dimensions(LxBxH):Encoder92
x69.5x24mm
Antennaboard84x39x7.6mm(Antennaheight26mm)
7. FCCStatements:
Notice:ThisdevicecomplieswithPart15oftheFCCRulesandwithRSS210ofIndustryCanada.
Operationissubjecttothefollowingtwoconditions:
(1)thisdevicemaynotcauseharmfulinterference,and
(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycause
undesiredoperation.
Notice:
Changesormodificationsmadetothisequipmentnotexpresslyapprovedby
FEIGELECTRONICmayvoidtheFCCauthorizationtooperatethisequipment.
Notice:ThisproducthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,
pursuanttopart15oftheFCCRules.These
limitsaredesignedtoprovidereasonableprotection
againstharmfulinterferenceinaresidentialinstallation.Thisequipmentgeneratesusesandcan
radiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,may
causeharmfulinterferencetoradiocommunications.However,thereisnoguaranteethat
interferencewill
notoccurinaparticularinstallation.Ifthisequipmentdoescauseharmful
interferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentoff
andon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowing
measures:
Reorientorrelocatethereceivingantenna
Increasetheseparationbetweentheequipmentandreceiver
Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhich
thereceiverisconnected
Consultthedealeroranexperiencedradio/TVtechnicianforhelp