User Manual
FEIGELECTRONICGmbHLangeStr.4D‐35781Weilburg,GermanyTel.:+49(0)6471/3109‐0Fax:+49(0)6471/3109‐99www.feig.deEmail:info@feig.de
PD_FSAS‐250_Eng_120102.Doc
TSTPD_FSAS 250KBit
MultiturnAbsoluteEncoderw/integrated
WirelessSafetySystemforindustrialdoors
–StationaryUnit
MountingandStartupmanual
!
ATTENTION
Thecontentofthedoorcontrollermanualandparticularlythesafetyinstructionsmustget
note!
1. Pinconnections:
Remarks:
- ForconnectionshieldedcableswithM12A‐encodedplugarerecommended.Theshield
hastobeconnectedtoearthgroundonlyonthecontrollerside.
- Thehousingoftheplugisnotallowedtobeconnectedtoearthground.
- NotusedwiresmustbeisolatedinsideofFU3P
‐ Theassemblingtolerancefromshaftcentertosensorcenterismaximum+/‐1mm(+/‐
0.039inch).
- TorqueforM3screw/magnetholderfixing:maximum0.4Nm
2. Connectionimageinsidewith:
2.1batterychange:
Disconnectingthebatteryeffectsclearingofpositionvaluesfromtheencoder!After
reconnectingthebatteryaRESETmustbedone.Donotshortorchargethebattery.Do
notstoreoroperatethesystemabovethespecifiedtemperaturerange.Connecting
theencoderwithswitchedonsupplyvoltageisnotallowed.
)TodoanResetyoumustmakeanshortcutbetweentheResetpins
X3‐2andX3‐1forashortmoment
3. Mountingofencoder:
TST
PD_FSAS