INSTALLATION ® OBID Cabinet Lock megalock-l up from Firmware 4.00 (with real time clock) (2) (1) Fig. 1: megalock-l layout right (layout left = mirror image) (1) Recommended door hole diameter 23 mm (2) max. door thickness 21.5 mm final public 2004-10-06 megalock-l-manual.
OBID® megalock-l Installation Note Copyright 1998 - 2004 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages.
OBID® megalock-l Installation Contents 1. Safety and warning notices – read before commissioning ............................................4 2. Basic functions of the megalock-l..........................................................................................5 2.1. Locking the megalock-l.........................................................................................................5 2.2. Unlocking the megalock-l .........................................................................
OBID® megalock-l Installation 1. Safety and warning notices – read before commissioning • The device may only be used for the purpose intended by the manufacturer. • The operating instructions have to be handed out to every user and kept in an easily accessible place. • Unacceptable changes as well as the use of spare parts and special features which are not sold or recommended by the manufacturer, may cause fire, electric shocks and injuries.
OBID® megalock-l Installation 2. Basic functions of the megalock-l (1) Rotary knob: With integrated LED display (red / green) and antenna for exchange between megalock-l and megaKey. (2) Battery compartment: Use special screwdriver to open (Type: ID MS.SSD-A). 2.1. Locking the megalock-l 1. Push rotary knob megalock-l is activated for 8 sec. (no indicator) 2. Present megaKey: The green LED flashes for a max. of 8 sec.
OBID® megalock-l Installation 3. Installation Installing: The electronic cabinet lock megalock-l is attached on the inside of a cabinet door using four screws. Start-up: Once the installation work is complete and all the locks tested, they are configured according the star-up procedure. Applying the reference plate: Stick the user reference plate only to a flat, grease- and dust-free surface. 4. Start-up procedure The following Start-up procedure is recommended. 4.1.
OBID® megalock-l Installation 4.2. Configuring the megalock-l with the "SetupKey" The SetupKey is used to configure the System-ID, the cabinet number, the operating mode and the group number in the megalock-l. Only than can the megalock-l be used in the system. An already configured megalock-l will no longer accept the SetupKey. To change the configuration of a megalock-l, the latter must first have been cleared using a valid ResetKey. CAUTION: Use only a SetupKey having the correct Group No.
OBID® megalock-l Installation 4.3. Configuring for standard/daylight saving time "DSTKey" The DSTKey (Daylight Saving Time Key) is used to configure both switchover points for daylight saving/standard time as well as the type of switchover in the megalock-l. The switchover rule for the time change is programmed on the DSTKey. By default the time change rule of Central Europe (Begin: last Sunday in March; End: last Sunday in October) are programmed on DSTKey.
OBID® megalock-l Installation Operation: 1. Program the time and date you want to set in the megalock-l on the ClockSetKey. 2. When the programmed time of day is reached the megalock-l is "wakened“ and you present the ClockSetKey. A time 5 seconds later than the actual time of day is written back to the ClockSetKey. After the clock is set the new time of day programmed into the ClockSetKey, the megalock-l acknowledges by flashing the green LED. 3.
OBID® megalock-l Installation 5. Resetting a megalock-l with the "ResetKey" Clearing a megalock-l may be necessary for example if a mistake was made in initialising (e.g. wrong cabinet number) or if a megalock-l needs to have a different configuration. NOTE The ResetKey is only accepted by the megalock-l if it is unlocked! Operation: 1. Activate megalock (push rotary knob) 2. You have 8 seconds to hold the ResetKey in front of the rotary knob in the sensing zone of the megalock-l antenna.
OBID® megalock-l Installation 7. Battery The battery in the megalock-l is designed for at least 40 actuations daily within a period of 3 years. The time when the battery needs to be replaced will depend however on the self-discharging of the battery and by climatic effects, especially cold temperatures. To summarize, the time to replace the battery depends on the following factors: 1. the number of actuations, 2. how long the battery has been installed, and 3.
OBID® megalock-l Installation ANNEX A Technical Data Dimensions (W x H x D): approx. 110 x 119 x 84 mm Weight: approx. 350 g (incl. battery) Protection class Temperature range IP 43 Operation Storage 0 °C to 60 °C -25 °C to 60 °C Relative humidity Battery Battery life expectancy Key-Medium 10 % to 90 % (non-condensing) Battery Pack (4 x Alkali Mignon-Cell (AA)) 3 years assuming 40 operations daily (43.
OBID® megalock-l Installation ANNEX B: Europe (CE) When properly used this radio equipment conforms to the basic requirements of Article 3 and the other relevant provisions of the R&TTE Directive 1999/5/EG of March 99. Equipment Classification according ETSI EN 300 330: Class 2 USA (FCC) FCC ID: PJMMLL02 This device complies with Part 15 of the FCC Rules.
OBID® megalock-l Installation ANHANG C: LED Blink-Codes LED Signal ¥ 1 x green (3 Sec) ¥ 1 x green ¥ 1 x red Description • Reset-Indicator (e.g. first activation after battery replacement) • OK (Action was successfully completed) • • Unknown megaKey Type Action is only allowed on unlocked megalock-l e.g. ResetKey or SetupKey. The present free-megaKey has locked another megalock-l.