User Manual
Table Of Contents
Identification System OBID
i-scan
Page 18 of 20 FEIG ELECTRONIC GmbH
5.2. Setting addresses for bus operation
For bus operation the Reader allows you to set the required bus address either using DIP switch
S2 or through the software.
a) Setting the bus address on S2 :
Addresses „0“ to „7“ can be set on S2.
To set the bus address using S2, the Reader must be set to software address „0“ (factory set-
ting).
Address Switch 1 Switch 2 Switch 3
0 OFF OFF OFF
1OFFOFF
ON
2OFF
ON
OFF
3OFF
ON ON
4
ON
OFF OFF
5
ON
OFF
ON
6
ON ON
OFF
7
ON ON ON
b) Setting the bus address through software
Addresses are assigned through the host computer. The software is used to assign addresses “0”
to “253” to the Reader.
Note:
Since all Readers are factory set to Address 0, they must be connected and configured one
after the other.