3.5. X6: Output (optocoupler isolated)
The transistor connections, collector and emitter, of the two optocoupler outputs are galvanically
isolated from the Reader electronics and brought out on Terminal X8 without any additional cir-
cuitry. The outputs must therefore be supplied externally.
Terminal Name Description
1O1-CCollector – Output 1
2 O1-E Emitter – Output 1
3 O2-C Collector – Output 2
4 O2-E Emitter – Output 2
For cable lengths greater than 3 m use shielded cable.
Notes:
• The outputs are configured for max. 24 V DC / 30 mA.
• Reversing the polarity or overloading the outputs will destroy the unit.
• The outputs are designed to switch resistive loads only.
Fig. 3.5-1: Internal wiring of the optocoupler outputs
X6
1
2
3
4
O1-C
O1-E
O2-C
O2-E
ID ISC.LR200