User Manual

Identification System OBID
i-scan
Page 10 of 20 FEIG ELECTRONIC GmbH
3.4. X7: Inputs (optocoupler isolated)
The optocoupler inputs on Terminal X7 are galvanically isolated from the Reader electronics and
must therefore be powered by a separate external DC supply. The input LED’s on the optocou-
plers have an internal input series resistor of 500 . For supply voltages above 10V the input cur-
rent must be limited to max. 20 mA by an additional external dropping resistor (see Table 3.4-1).
Terminal Name Description
1 IN1+ + Input 1
2 IN1- - Input 1
3 IN2+ + Input 2
4 IN2- - Input 2
For cable lengths greater than 3 m use shielded cable.
Notes:
The inputs are designed for a maximum input voltage of 24 V DC and an input current of
maximum 20 mA
Reversing the polarity or overloading the inputs will destroy the unit
The supply voltage of the Reader may not be used for driving the inputs, since the
added noise may result in reduced effective reading distances.
Fig. 3.4-1: Internal and possible external wiring of the optocoupler inputs
External voltage U
ext
Required external dropping
resistor R
ext
5 V ... 10 V ---
11 V ... 15 V
270
16 V ... 20 V
560
21 V ... 24 V
820
Table 3.4-1: Required external dropping resistor R
ext
X7
2
3
4
IN1 +
IN1 -
IN2 +
IN2 -
R
1
int
R
int
R
ext
R
ext
ID ISC.LRM200
U
ext.
U
ext.