User's Manual
Table Of Contents
- Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen
- Leistungsmerkmale des Readermoduls ID ISC.M02
- Montage und Anschluss
- Funkzulassungen
- Technische Daten
- Safety Instructions / Warning - Read before start-up !
- Performance Characteristics of the ID ISC.M02 Reader Module
- Installation and wiring
- Radio Approvals
- Technical Data

OBID
®
Installation ID ISC.M02
FEIG ELECTRONIC GmbH Page 42 of 42 M20301-0de-ID-B.doc
E N G L I S H
10. Technical Data
Mechanical Data
• Dimensions ( W x H x D )
50mm x 50mm x 14 mm
• Connector
10 pol. Pin-Connector
Electrical Data
Supply voltage
Version –B
5 V DC ± 5%
• Power Consumption
max. 1 W
• Operating Frequency
13.56 MHz
• RF Transmitting Power
90 mW ± 2 dB
• Antenna
Internal Antenna, 48mm x 48mm
Optional: external Antenna
• Interfaces
Version –B
RS232 – Level TTL, Data /Clock-Interface
Functional Characteristics
• EEPROM (for parameters)
1 kB
(10.000 write cycles)
• FLASH
64 kB
(software update on interface possible)
• Supported Transponders
• ISO15693 (I•Code SLI, Tag-It HFI, my-d vicinity,
STM LRI512), I•Code 1
• Optional:
SAM (Security Access Module),
e.g. for my-d vicinity
• Optical Indicators
2 LED´s
Ambient
• Temperature Range
– Operating
– Storage
-20°C to +70°C
-40°C to +85°C
Applicable Norms
• Radio Approval
– Europe
– USA
EN 300 330
FCC 47 CFR Part 15
• EMC
EN 301 489
• Safety
EN 60950