3.2.1. Supply voltage
The ID CPR.M02 must be supplied only by a regulated power supply. If switching power supplies
are used with the module, be sure that there is adequate filtering. Noise from the power supply can
result in a reduction of the read/write range of the module. The cable length from the power supply
should be as short as possible, and should in any case not exceed 3 m.
Description
X1
Pin no.
Function
ID CPR.M02
8 VCC *
+ 5 V DC ± 5%
9, 4 GND ** GND
* Use only regulated power supplies !
** GND-Pins 4 and 9 are to be connected directly to each
other on the Reader Module
Table 3.2.1-1: Pin assignments for X1
NOTE:
• Reversing the polarity of the supply voltage may destroy the device.
• Supply voltages outside the specifications may destroy the device.