User Manual

OBID
®
classic-pro Installation ID CPR74
FEIG ELECTRONIC GmbH Page 9 of 20
CPR74-Manual M60610-
0e.docx
NOTICE:
Only one host interface can be used at the same time. Using several host interfaces at
the same time can force malfunctions.
The reader has to supplied by a limited power supply (e.g. NEC Class 2/LPS power sup-
ply) according IEC EN 60950-1 chapter 2.5, only
Use only regulated power supply’s.
The connection cable (RS232TTL, USB, VCC) should be as short as possible and must be
shorter than 3 m to reduce the influence of noise.
Reversing the polarity of the supply voltage may destroy the device.
Supply voltages outside the specifications may destroy the device.
If switching power supplies are used with the module, be sure that there is adequate fil-
tering.
Noise from the power supply can result in a reduction of the read/write range of the
module.
4.2. Digital Outputs
The Figure 5 shows the circuit diagram of the digital outputs OUT1 – OUT3. The digital outputs are
intended for the connection of external LED’s.
Figure 5: Wiring of digital outputs OUT1...3