User's Manual

OBID
®
classic-pro Installation ID CPR.03-VP/AB-A
FEIG ELECTRONIC GmbH
Page 7 of 11
4 Installation
The ID CPR.03-VP/AB-A is designed to be wall-mounted with or without a 60 mm flush-mounting
box
4.1
Mounting
The reader should not be mounted directly onto conductive materials, such as metal surfaces,
metal frames (reinforcement) or metal-plated surfaces, as these surfaces will reduce the
reader's range. The clearance to such surfaces should be at least 30 mm.
The distance between readers of the same design should not be less than 50 cm.
Before final installation, the planned installation site should be checked for suitability.
Only install the reader after successful commissioning. The power supply must be discon-
nected for configuration (see also : 4.3 Configuration).
Use the screws provided (3.2 x 25 mm) for installation on 60 mm DIN flush-mounting boxes.
For other installation methods use 3 mm countersunk-head screws to DIN 963 or with a coun-
tersunk head max. diameter of head 5.6 mm.
TOP
Assembling Disassembling