User's Manual
OBID
®
classic-pro Installation ID CPR.03-VP/AB-A
FEIG ELECTRONIC GmbH
Page 10 of 11
5 Normal Operating Mode
Idle State (no Transponder detected):
In idle state the reader is searching permanent for a Transponder.
red LED = active
Transponder detected:
After a Transponder is detected by the ID CPR.03-VP/AB-A the data's are transmitted via
data-/clock interface once and the beeper sounds for a short time. At the same time the
red LED turns off for timeout time which is configured (default configuration 2 sec.).
To transmit the data's a second time the Transponder must leave the detection field of the
ID CPR.03-VP/AB-A for more then 1,5 seconds.
UID Length Error
If the Transponder UID is shorter than configured in ID CPR.03-VP/AB-A a length error is
signalized with 2 short beeps. In this case no data's are transmitted via data-/clock inter-
face.
5.1 Digital Inputs
LED red:
Activates the red LED, as long as the input is connected to GND.
LED green:
Activates the green LED and deactivates the red LED, as long as the input is connected to
GND.
Beeper:
Activates the beeper LED, as long as the input is connected to GND.
Hold:
Will not accept a transponder, as long as the input is connected to GND.