INSTALLATION ® OBID classic-pro ID CPR.
OBID® classic-pro Installation ID CPR.03-VP/AB-A Note © Copyright 2006 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority.
OBID® classic-pro Installation ID CPR.03-VP/AB-A Contents 1 Safety Instructions / Warning - Read before start-up ! 4 2 Introduction 4 3 Technical Specifications 5 Dimensions ..................................................................................................................................6 3.2 4 Approval .........................................................................................................................6 Installation 7 4.1 Mounting ......................
OBID® classic-pro 1 Installation ID CPR.03-VP/AB-A Safety Instructions / Warning - Read before start-up ! • The device may only be used for the intended purpose designed by for the manufacturer. • The operation manual should be conveniently kept available at all times for each user. • Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries.
OBID® classic-pro 3 Installation ID CPR.03-VP/AB-A Technical Specifications Housing Plastic ABS (sealed-in electronics) Color gray - beige Weight approx. 170 g Protection class IP 65 Power Supply 9 - 15 V DC Power Consumption max. 2,6 W Temperature range Operating -25 °C to +60 °C Storage -40 °C to +85 °C Relative humidity 95% (not condensing) Antenna internal Operating Frequency 13,56 MHz Transmitting power 200 mW ± 2 dB Supported Transponder (read UID) • ISO14443A: e.g.
OBID® classic-pro 3.1 Installation ID CPR.03-VP/AB-A Dimensions 75 17 120 60 83,5 7,7 4,2 3.2 Approval When properly used this radio equipment conforms to the essential requirements of Article 3 and the other relevant provisions of the R&TTE Directive 1999/5/EC of March 99. Equipment Classification according to ETSI EN 300 330 and ETSI EN 301 489: Class 2 FCC ID: PJMCPR03 This device complies with Part 15 of the FCC Rules.
OBID® classic-pro 4 Installation ID CPR.03-VP/AB-A Installation The ID CPR.03-VP/AB-A is designed to be wall-mounted with or without a 60 mm flush-mounting box 4.1 Mounting • The reader should not be mounted directly onto conductive materials, such as metal surfaces, metal frames (reinforcement) or metal-plated surfaces, as these surfaces will reduce the reader's range. The clearance to such surfaces should be at least 30 mm.
OBID® classic-pro 4.2 Installation ID CPR.03-VP/AB-A Connection Colour Function red Vcc (+9 to +15 V DC) black GND* green Data / Data0 white Clock / Data1 violet CLS / Card Present grey LED green brown LED rot yellow Beeper blue Hold pink RS232-TTL (Rx) red / blue RS232-TTL (Tx) grey / pink - N.C.
OBID® classic-pro 4.3 Installation ID CPR.03-VP/AB-A Configuration Configuration is carried out by means of a ConfigCard. An ISO 15693 transponder can be used as ConfigCard (e.g. Infineon my-d, SFR55V10P, Philips I-CODE SLI, etc.) The configuration data are stored in a specified read/write data block on the transponder. The transponder is also provided with identifiers which enable recognition as the ConfigCard.
OBID® classic-pro 5 Installation ID CPR.03-VP/AB-A Normal Operating Mode Idle State (no Transponder detected): In idle state the reader is searching permanent for a Transponder. red LED = active Transponder detected: After a Transponder is detected by the ID CPR.03-VP/AB-A the data's are transmitted via data-/clock interface once and the beeper sounds for a short time. At the same time the red LED turns off for timeout time which is configured (default configuration 2 sec.).
OBID® classic-pro 5.2 Installation ID CPR.03-VP/AB-A Data-/Clock Interface Depending on the reader configuration the hexadecimal coded UID (max. 10 byte) of the Transponder could be transmitted in different formats via data-/clock interface. Details are described in ID CPR.03-VP/AB-A Manual (Document No: H60100-#e-ID-B) 5.3 Asynchronous Interface: RS232-TTL The RS232-TTL Interface is designed only for firmware update. The firmware is stored in a flash chip.