FEIG ELECTRONIC GmbH Page 47 of 50 M71104-1e-ID-B.doc
Permissible overall transmitting
power per antenna gate
– EU-territory (per EN 300 330) and
other CEPT nations
– USA (per. FCC Part 15)
8.0 W
8.0 W
Outputs
– 1 Optocoupler
– 1 Differential Output
– 1 Relay ( 1 x Changeover)
24 V / 30 mA
Reader Synchronisation
24 V / 2 A for Alarm Kit
Inputs
– 1 Optocoupler
– 1 Differential Input
Max. 24 V
20 mA
Reader Synchronisation
Interfaces
RS232
RS484 / RS422
Ethernet (TCP/IP)
Compact Flash II
(WLAN)
Protocol Modes FEIG ISO HOST
BRM (Data Filtering and Data Buffering)
Scan Mode (RS 232/485/422)
Notification Mode (TCP/IP)
Supported Transponders ISO 15693, ISO 18000-3-A, (EM HF ISO
Chips, Fujitsu HF ISO Chips, KSW Sensor
Chips, Infineon my-d, NXP I-Code , STM ISO
Chips, TI Tag-it)
NXP I-code 1, I-Code UID, I-Code EPC
Ranges / pass-through width in gate
with power splitter
– One tag orientation
– All tag orientations
approx. 105 cm**
approx. 90 cm***
Ranges / pass-through width in gate
with multiplexer
– One tag orientation
– All tag orientations
approx. 120 cm**
approx. 95 cm***
Antenna connection 1 x SMA plug (50 )
Antenna connector cable