Installation Manual

OBID i-scan
®
Installation ID ISC.ANT1300/680-A
FEIG ELECTRONIC GmbH Page 45 of 50 M71104-1e-ID-B.doc
The Reader needs to be configured as follows depending on the installation location:
Parameter USA / Canada / Europe
(42dBuA/m)
General
RF-Power – CFG 3 maximum 8 W
Downlink RF Modulation – CFG
20 / RF-Modulation
15%
ISO15693
Downlink RF Modulation – CFG
4 / ISO-MODE / MOD
10%
Downlink RF Data coding –
CFG 4 / ISO-MODE / FAST
Fast (1/4) or Normal (1/256)
Timeslots - CFG 4 / ISO-MODE
/ NO-TS
1 or 16 Timeslots
Inverntory Command Option –
CFG 4 / ISO-CMD-OPTION /
BREAK
Complete Timeslot length at
„NO TAG“