Installation Manual

OBID i-scan
®
Installation ID ISC.ANT1300/680-A
FEIG ELECTRONIC GmbH Page 28 of 50 M71104-1e-ID-B.doc
4.3.3 Configuration of a Gate antenna with Multiplexer
Connect the components as shown in Fig. 12.
Fig. 12: Connecting the components for a gate consisting of Type A with multiplexer
The coax cables have fixed lengths and may not be shortened and therefore need to be tied into
small loops (see Fig. 13:Tying the cables). Tie all cables as far away from the antenna conductor
as possible. The cables must never be allowed to contact the aluminum tube.
Fig. 13:Tying the cables
DC Power supply
24V
X2
X3
3,60m
2 Tuning boards of
antennas ID ISC.ANT1300/680
Multiplexer
ID ISC.ANT.MUX-A-M
Long Range Reader
ID ISC.LRM2000
X1
1,35m
IN1
OUT1
OUT2
3,60m
X1
Torrid core
X9, Pin1+3
Pos.8
Pos.2
Pos.1
Pos.4
Pos.3
Pos.7