User's Manual
Table Of Contents
● OFF mode
Entering this mode, turn off the compressor and fan .
● Tank full
Dspite any mode, stop the compressor right now when tank is full. If tank still full
with in one minute then off fan otherwise fan will still running and system will inform
receiver per 10second. When tank in full tank full led will flash and beep three
times and then beep per second. Display show room humidity. When tank water
empty then tank full led will off and keep last mode running.
LED
● Tank full led:
When the tank is full, Tank full led flashing, buzzer beep three times and then beep
per one second.If tank not full led will off.Display show the room humidity. When
tank full flashing, stop all normal working , but keep original display condition. For
example when tankf full system in dehumidity condition , the compressor stops
and fan will stop after one-minute running. When tank is empty, dehumidifier start
running automaticly, and come back to last mode running and r(compressor have
3 minute protection function ).
● Function led
★ When Choose the allow mode, the correspondent led will on.
★ If have not choose any mode, OFF led will on, the display show room humidity.
PROTECTION FUNDTION
● Sensor error
★ When detecting abnormal (open or short), stop all action(that mean turn off the
compressor and fan), refer to sensor error solution.
● Tank switch
★ When tank switch didn’t install , system turn off the compressor and fan,
Tank full led flashing, the monitor display the humidity in the room, original
running mode led on.
● Tank full
★ When tank is full, turn off the compressor and fan, Tank full led flashing, the
monitor display the humidity in the room, original running mode led bright.
● Compressor delay(compressor have 3 minute protection function)
★ When machine is running initially, the compressor needs three minutes stop