correct not.
★ Economy mode : economy led will on .
if room humidity over or equal 65% fan and compressor on(if compressor stop
before, it is on at the three minutes safe time, if safe time is not arrive, it wont
run. Over the safe time,than it will run) start dehumidity . When the room
humidity lower 65%, compressor stop but fan still running when room humidity
continue lower 70% within one minute fan will off. But Holmes hope fan stop
after running 3 minute. Norm will check BDQ24 function.
if humidity is over and >= 70%, turn on the fan, than turn on and the
compressor on and have three minutes safe time protection. When tank is full,
refer to〔Tank full〕item.
● Continuous mode
Continuous led on ,compressor(compressor have 3 minute protection function )
and fan continue running . When tank is full, turn off the compressor but fan is
going on, after one minute if still tank full then fan off. Continuous led still on and
display room humidity. Tank is full description please refer to 〔Tank full〕item.
● 45%-55% mode:
45%-55% led on. When room humidity is over or equal 45%, then
compressor(compressor have 3 minute protection function ) and fan continue
running. When the room humidity is lower 45%, turn off the compressor but fan still
running(Please check does fan stop after running 3 minute). If the room humidity
continue lower 50% within one minute then fan off. If humidity is over or equal
50%, then compressor(compressor have 3 minute protection function ) and fan
continue running. When the room humidity is lower 45%, turn off the compressor
but fan still running(Please check does fan stop after running 3 minute). If the room
humidity continue lower 50% within one minute then fan off. When tank is full, refer
to 〔Tank full〕item.
● 55%-65% mode
55%-65% led on. When room humidity is over or equal 55%, then
compressor(compressor have 3 minute protection function ) and fan continue
running. When the room humidity is lower 55%, turn off the compressor but fan still
running(Please check does fan stop after running 3 minute). If the room humidity
continue lower 60% within one minute then fan off. If humidity is over or equal
55%, then compressor(compressor have 3 minute protection function ) and fan
continue running. When the room humidity is lower 55%, turn off the compressor
but fan still running(Please check does fan stop after running 3 minute). If the room
humidity continue lower 60% within one minute then fan off. When tank is full, refer