Manual

FEC Micro Nutrunner Operations Manual Chapter 7: System Operations (Rev. 2.1: 12/12)
Page 7-3
7.1.2 Fastening Preset / Result displays.
w[D-NO] Data number indicator (2 digits).
Indicates the Display mode and data type (number)
No digit: Status Display mode
One digit: Real Time Display mode
Two digits: Parameter Display mode
Digit on the left : Fastening Result Display mode
When an Abnormal occurs the abnormal Sub Code will be displayed here.
w[DATA] Data value indicator (4 digits).
Displays the data specified by [D-NO] while in any display mode (refer to applicable section).
w[PARM] Parameter number/Abnormal number indicator (2 digits).
Display for the parameter number of the last fastening parameter run when in Fastening
Results Display mode, or the selected parameter when in Parameter Display or Setup mode.
Also displays an abnormal code during an abnormal condition. When the CAL switch is
pressed, "E" is shown if the FULL-SCALE preset value is missing or a wrong tool is
connected (Refer to Chapter 9).
Abnormal “A9” Display Parameter No. 1 Cal “E” Fault
Sub code 0 Data #10
7.1.3 Fastening Presetting / Result Display Controls.
wMODE button
PUsed to change modes. (Refer to 7.2)
PUsed to move the cursor while programming. (Refer to 7.3)
wSET button
PUsed to enter Data Edit mode and to confirm data setting changes.
w[] and [] Cursor push buttons (vertical arrows).
PUsed to scroll through available (8) parameter numbers. (PARM)
PUsed to scroll through available data preset items. (D-NO)
PUsed to change display data values. (DATA)
Used as YES/NO acknowledge for Tool type and Torque unit changes. (Fig 7-3-6)
D-NOPARM
D-NO
D-NOPARM
PARM
D-NOPARM
D-NO
D-NOPARM
PARM